Effect of central corneal thickness on dynamic contour tonometry and Goldmann applanation tonometry in primary open-angle glaucoma.

نویسندگان

  • Matthias C Grieshaber
  • Andreas Schoetzau
  • Claudia Zawinka
  • Josef Flammer
  • Selim Orgul
چکیده

OBJECTIVE To compare the dependence of dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) on central corneal thickness (CCT) in primary open-angle glaucoma. METHODS In a prospective study, the interocular (right vs left eye) difference in intraocular pressure measured by DCT and GAT was compared with the interocular CCT difference in 125 patients with primary open-angle glaucoma. RESULTS Dynamic contour tonometry measurements (mean +/- SD, 19.4 +/- 4.1 mm Hg) were significantly (P=.004) higher than GAT measurements (mean +/- SD, 15.5 +/- 3.4 mm Hg), correlating significantly with each other (r(2)=0.82, P<.001). The interocular difference in intraocular pressure correlated significantly with the interocular CCT difference for GAT (r=0.30, P=.001) and DCT (r=0.23, P=.02) readings. Dynamic contour tonometry and GAT intraocular pressure differences significantly increased with older age (slope, 0.033 [95% confidence interval, 0.002-0.064] mm Hg/y; P=.03) but not with thicker CCT (slope, 0.006 [95% confidence interval, -0.003 to 0.017] mm Hg/mum; P=.22). CONCLUSIONS In this series, GAT and DCT measurements were dependent on CCT in patients with primary open-angle glaucoma. Because intraocular pressure differences between DCT and GAT were independent of CCT, DCT and GAT are susceptible to similar measurement biases depending on CCT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Using CorvisST tonometry to assess glaucoma progression

PURPOSE To investigate the utility of the Corneal Visualization Scheimpflug Technology instrument (CST) to assess the progression of visual field (VF) damage in primary open angle glaucoma patients. METHOD A total of 75 eyes from 111 patients with primary open-angle glaucoma were investigated. All patients underwent at least nine VF measurements with the Humphrey Field Analyzer, CST measureme...

متن کامل

The usefulness of CorvisST Tonometry and the Ocular Response Analyzer to assess the progression of glaucoma

Corneal Visualization Scheimpflug Technology (CST) and Ocular Response Analyzer (ORA) measurements were carried out in 105 eyes of 69 patients with primary open-angle glaucoma. All patients had axial length (AL), central corneal thickness (CCT), intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) and eight visual fields (VF)s with the Humphrey Field Analyzer. VF progression was...

متن کامل

Assessment of corneal biomechanical properties in normal tension glaucoma and comparison with open-angle glaucoma, ocular hypertension, and normal eyes.

PURPOSE To assess the biomechanical properties of corneas in patients with normal tension glaucoma (NTG) and to compare them with those of patients with primary open-angle glaucoma (POAG), ocular hypertension (OHT), and normal controls (N). METHODS Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann intraocular pressure (IOPg), and corneal compensated IOP (IOPcc) were obtained ...

متن کامل

Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension.

BACKGROUND/AIMS Recent studies have revealed patients with ocular hypertension to have thicker than normal central corneas and those with normal tension glaucoma to have thinner than normal ones, as determined by ultrasonic pachymetry. Since corneal thickness measurements and applanation tonometric estimates of intraocular pressure (IOP) correlate positively, monitoring of the former parameter ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 125 6  شماره 

صفحات  -

تاریخ انتشار 2007