Efficacy of a detector tube method in formaldehyde measurement.

نویسندگان

  • Michiyo Azuma
  • Yoko Endo
  • Takeji Miyazaki
  • Yoko Hikita
  • Hiroki Ikeda
  • Yoshihumi Moriya
  • Ichiro Hara
  • Shunichi Araki
چکیده

In order to determine the efficacy of a detector tube method in formaldehyde (HCHO) measurement, we performed a chamber experiment and a field study. The experiment clearly showed that the value obtained by the detector tube method was significantly correlated to that obtained using an active-DNPH method, and was not influenced by the coexistence of toluene, xylene or carbon monoxide, but was by acetaldehyde. In the field study, we investigated 171 rooms in 81 houses. Indoor air was simultaneously sampled for 30 minutes by both an active-DNPH method and the detector tube method. The mean HCHO concentration in the 171 rooms was 0.110 +/- 0.089 ppm determined by the active-DNPH method and 0.12 +/- 0.10 ppm by the detector tube method. Regression analysis showed that the two measures closely correlated with a regression equation Y=1.057 X + 0.002 (r=0.912, p<0.0001), where X is the HCHO concentration determined by the active-DNPH method and Y is that determined by the detector tube method. The mean acetaldehyde concentration in the 171 rooms was 0.024 +/- 0.018 ppm using the active-DNPH method, and no correlation was found between acetaldehyde concentrations using the active-DNPH method and the values obtained by the detector tube method. Therefore, this study clearly showed that the detector tube method is not only simple and fast but also precise in measuring HCHO in indoor air.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Formaldehyde measurement based on its electrocatalytic oxidation by Ni-TiO2 nanoparticles/chitosan modified carbon paste electrode as an effective method

In this work, for the first time, a new and effective bulk modified carbon paste electrode (CPE) was prepared by TiO2 nanoparticles and chitosan and then Ni2+ ions were incorporated to this electrode by immersion of the modified electrode in nickel chloride solution. The values of electron transfer coefficient, charge-transfer rate constant and electrode surface coverage f...

متن کامل

Formaldehyde measurement based on its electrocatalytic oxidation by Ni-TiO2 nanoparticles/chitosan modified carbon paste electrode as an effective method

In this work, for the first time, a new and effective bulk modified carbon paste electrode (CPE) was prepared by TiO2 nanoparticles and chitosan and then Ni2+ ions were incorporated to this electrode by immersion of the modified electrode in nickel chloride solution. The values of electron transfer coefficient, charge-transfer rate constant and electrode surface coverage f...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Validated UV-Vis Spectrophotometric Method for Determination of Gabapentin using Acetyl Acetone and Formaldehyde Reagents

Gabapentin is an anticonvulsant widely used in the treatment of epilepsy.An accurate and validated spectrophotometric method was developed as an alternative method to determine gabapentin in pharmaceutical products. This is a simple, accurate, precise, selective and visible spectrophotometric method. The method is based on the measurement of drug absorbance as a result of yellow solution format...

متن کامل

Measurement of formaldehyde concentrations in a subatmospheric steam-formaldehyde autoclave.

A method has been developed for measuring formaldehyde concentrations in a subatmospheric steam-formaldehyde autoclave. Data obtained using this method indicate that the concentration of formaldehyde in the chamber atmosphere is not homogeneous and that it decreases rapidly with time. The penetration of formaldehyde vapour into narrow tubes has also been investigated and was shown to be depende...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Industrial health

دوره 41 4  شماره 

صفحات  -

تاریخ انتشار 2003