Change in end-tidal carbon dioxide outperforms other surrogates for change in cardiac output during fluid challenge.
نویسندگان
چکیده
Background During fluid challenge, volume expansion (VE)-induced increase in cardiac output (Δ VE CO) is seldom measured. Methods In patients with shock undergoing strictly controlled mechanical ventilation and receiving VE, we assessed minimally invasive surrogates for Δ VE CO (by transthoracic echocardiography): fluid-induced increases in end-tidal carbon dioxide (Δ VE E'CO2 ); pulse (Δ VE PP), systolic (Δ VE SBP), and mean systemic blood pressure (Δ VE MBP); and femoral artery Doppler flow (Δ VE FemFlow). In the absence of arrhythmia, fluid-induced decrease in heart rate (Δ VE HR) and in pulse pressure respiratory variation (Δ VE PPV) were also evaluated. Areas under the receiver operating characteristic curves (AUC ROC s) reflect the ability to identify a response to VE (Δ VE CO ≥15%). Results In 86 patients, Δ VE E'CO2 had an AUC ROC =0.82 [interquartile range 0.73-0.90], significantly higher than the AUC ROC for Δ VE PP, Δ VE SBP, Δ VE MBP, and Δ VE FemFlow (AUC ROC =0.61-0.65, all P <0.05). A value of Δ VE E'CO2 >1 mm Hg (>0.13 kPa) had good positive (5.0 [2.6-9.8]) and fair negative (0.29 [0.2-0.5]) likelihood ratios. The 16 patients with arrhythmia had similar relationships between Δ VE E'CO2 and Δ VE CO to patients with regular rhythm ( r 2 =0.23 in both subgroups). In 60 patients with no arrhythmia, Δ VE E'CO2 (AUC ROC =0.84 [0.72-0.92]) outperformed Δ VE HR (AUC ROC =0.52 [0.39-0.66], P <0.05) and tended to outperform Δ VE PPV (AUC ROC =0.73 [0.60-0.84], P =0.21). In the 45 patients with no arrhythmia and receiving ventilation with tidal volume <8 ml kg -1 , Δ VE E'CO2 performed better than Δ VE PPV, with AUC ROC =0.86 [0.72-0.95] vs 0.66 [0.49-0.80], P =0.02. Conclusions Δ VE E'CO2 outperformed Δ VE PP, Δ VE SBP, Δ VE MBP, Δ VE FemFlow, and Δ VE HR and, during protective ventilation, arrhythmia, or both, it also outperformed Δ VE PPV. A value of Δ VE E'CO2 >1 mm Hg (>0.13 kPa) indicated a likely response to VE.
منابع مشابه
Association Between End-Tidal Carbon Dioxide Pressure and Cardiac Output During Fluid Expansion in Operative Patients Depend on the Change of Oxygen Extraction
In a model of hemorrhagic shock, end-tidal carbon dioxide tension (EtCO2) has been shown to reflect the dependence of oxygen delivery (DO2) and oxygen consumption (VO2) at the onset of shock. The objectives of the present study were to determine whether variations in EtCO2 during volume expansion (VE) are correlated with changes in oxygen extraction (O2ER) and whether EtCO2 has predictive value...
متن کاملتأثیر تهویه با حجمهای جاری متفاوت و تهویه دقیقهای ثابت بر روی دیاکسید کربن انتهای بازدمی
Background & Aims: Elimination of carbon dioxide is related to the alveolar ventilation, respiratory rate and tidal volume. The aim of this study to determine the effect of mechanical ventilation with different tidal volumes and constant minute ventilation on the end tidal Co2 and oxygen saturation during general anesthesia and to seek optimum parameters of mechanical ventilation during gener...
متن کاملEnd-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning
Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...
متن کاملMeasuremient of end-tidal carbon dioxide concentration during cardiopulmonary resuscitation
End-tidal carbon dioxide concentrations were measured prospectively in 12 cardiac arrest patients undergoing cardiopulmonary resuscitation (CPR) in an accident and emergency department. The end-tidal carbon dioxide (CO2) concentration decreased from a mean (+ SD) of 4-55 + 0.88% 1 min after chest compression and ventilation was established, to values ranging from 2-29 + 0-84% at 2min to 1-56 + ...
متن کاملMeasurement of end-tidal carbon dioxide concentration during cardiopulmonary resuscitation.
End-tidal carbon dioxide concentrations were measured prospectively in 12 cardiac arrest patients undergoing cardiopulmonary resuscitation (CPR) in an accident and emergency department. The end-tidal carbon dioxide (CO2) concentration decreased from a mean (+/- SD) of 4.55 +/- 0.88% 1 min after chest compression and ventilation was established, to values ranging from 2.29 +/- 0.84% at 2 min to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 118 3 شماره
صفحات -
تاریخ انتشار 2017