Factors contributing to airborne particle dispersal in the operating room

نویسندگان

  • Chieko Noguchi
  • Hironobu Koseki
  • Hidehiko Horiuchi
  • Akihiko Yonekura
  • Masato Tomita
  • Takashi Higuchi
  • Shinya Sunagawa
  • Makoto Osaki
چکیده

BACKGROUND Surgical-site infections due to intraoperative contamination are chiefly ascribable to airborne particles carrying microorganisms. The purpose of this study is to identify the actions that increase the number of airborne particles in the operating room. METHODS Two surgeons and two surgical nurses performed three patterns of physical movements to mimic intraoperative actions, such as preparing the instrument table, gowning and donning/doffing gloves, and preparing for total knee arthroplasty. The generation and behavior of airborne particles were filmed using a fine particle visualization system, and the number of airborne particles in 2.83 m3 of air was counted using a laser particle counter. Each action was repeated five times, and the particle measurements were evaluated through one-way analysis of variance multiple comparison tests followed by Tukey-Kramer and Bonferroni-Dunn multiple comparison tests for post hoc analysis. Statistical significance was defined as a P value ≤ .01. RESULTS A large number of airborne particles were observed while unfolding the surgical gown, removing gloves, and putting the arms through the sleeves of the gown. Although numerous airborne particles were observed while applying the stockinet and putting on large drapes for preparation of total knee arthroplasty, fewer particles (0.3-2.0 μm in size) were detected at the level of the operating table under laminar airflow compared to actions performed in a non-ventilated preoperative room (P < .01). CONCLUSIONS The results of this study suggest that surgical staff should avoid unnecessary actions that produce a large number of airborne particles near a sterile area and that laminar airflow has the potential to reduce the incidence of bacterial contamination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultraviolet in-room air disinfection and recirculation greatly reduces viable airborne particle concentrations in the operating room setting

Objective. To evaluate the effectiveness of a novel in-room air disinfection technology through the use of real-time viable airborne particulate counting. Methods. Using laser particle fluorescence techniques in real time, airborne viable particle concentrations were obtained before and after air treatment with the in-room C-UVC device in an active hospital operating room setting. Results. A la...

متن کامل

Monitoring of airborne bacteria and aerosols in different wards of hospitals - Particle counting usefulness in investigation of airborne bacteria.

INTRODUCTION AND OBJECTIVE The presence of airborne bacteria in hospital environments is of great concern because of their potential role as a source of hospital-acquired infections (HAI). The aim of this study was the determination and comparison of the concentration of airborne bacteria in different wards of four educational hospitals, and evaluation of whether particle counting could be pred...

متن کامل

Differences in the correlation between microbiological air sampling and particle counting in operating theatres and hospital cleanrooms

Introduction / objectives The process of environmental monitoring in cleanrooms of clinical pharmacy and operating theatres is difficult, the measurement of bio burden is time consuming and the result is available several days after the operation. This study examines the correlation between the number of airborne bacteria and particles in operating theatres and cytostatic compounding cleanrooms...

متن کامل

بررسی غلظت باکتری ها در هوای داخل بیمارستان مرکز طبی کودکان تهران

Background and Objectives: Atmospheric transport is a key mode of microbial dispersal and the transmission of airborne microbe can have significant impacts on human health. The main objective of this study was to determine the concentrations of airborne bacteria in a children.s hospital.Materials and methods: Three sampling points were selected. Airborne bacteria were collected with 6 days inte...

متن کامل

Forced-air warming: a source of airborne contamination in the operating room?

Forced-air-warming (FAW) is an effective and widely used means for maintaining surgical normothermia, but FAW also has the potential to generate and mobilize airborne contamination in the operating room.We measured the emission of viable and non-viable forms of airborne contamination from an arbitrary selection of FAW blowers (n=25) in the operating room. A laser particle counter measured parti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017