Influence of photoisomers in bilirubin determinations on Kodak Ektachem and Hitachi analysers in neonatal specimens study of the contribution of structural and configurational isomers.

نویسندگان

  • J M Gulian
  • C Dalmasso
  • V Millet
  • D Unal
  • M Charrel
چکیده

We compared data obtained with the Kodak Ektachem and Hitachi 717 Analysers and HPLC from 83 neonates under phototherapy. Total bilirubin values determined with the Kodak and Hitachi are in good agreement, but we observed a large discrepancy in the results for conjugated (Kodak) and direct (Hitachi) bilirubin. HPLC revealed that all the samples contained configurational isomers, while only 7.7% and 30.8% contained conjugated bilirubin and structural isomers, respectively. We developed a device for the specific and quantitative production of configurational or structural isomers, by irradiation with blue or green light. In vitro, total bilirubin values are coherent for the routine analysers in the presence of configurational or structural isomers. With configurational isomers, unconjugated bilirubin (Kodak) is lower than total bilirubin (Kodak), and conjugated bilirubin (Kodak) is always equal to zero, so the apparatus gives a false positive response for delta bilirubin. In contrast, the direct bilirubin (Hitachi) is constant. Furthermore, in the presence of structural isomers, unconjugated bilirubin (Kodak) is unexpectedly higher than total bilirubin (Kodak), conjugated bilirubin (Kodak) is proportional to the quantity of these isomers, and direct bilirubin (Hitachi) is constant. The contribution of photoisomers in bilirubin measurements is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of total and conjugated bilirubin determination during the neonatal period.

During the neonatal period, total and conjugated bilirubin determinations are necessary to identify the origin of jaundice, to predict its evolution and to treat it. We discuss the results obtained in 108 neonates (less than 15 days old), undergoing phototherapy or not, using a colorimetric diazo reaction and dual wavelength reflectance with a Kodak Ektachem analyzer. Concerning total bilirubin...

متن کامل

Determination of conjugated and total bilirubin in serum of neonates, with use of bilirubin oxidase.

A new, simple, and rapid assay for conjugated bilirubin that does not require serum-matrix standards was developed by using the enzyme bilirubin oxidase (EC 1.3.3.5). This procedure can also be modified to measure total bilirubin. Measurements from these assays were compared with results obtained with the Sigma 605 (Jendrassik-Gróf method), Sigma 550/551 (Walters-Gerarde method), and Kodak Ekta...

متن کامل

Methotrexate interferes with determinations of conjugated bilirubin with the Kodak Ektachem 400.

Immediately after intravenous infusion of a high dose (concentration in serum greater than 1000 mumol/L) of methotrexate, the apparent conjugated bilirubin (Bc) concentrations in serum of two osteosarcoma patients, as measured by the Kodak Ektachem 400 analyzer, were greater than the corresponding total bilirubin concentrations, but decreased as the concentrations of methotrexate in serum decre...

متن کامل

Measuring blood glucose in neonatal units: how does hemocue compare?

Rapid and reliable determination of blood glucose concentration is essential during the neonatal period to prevent adverse neurodevelopmental outcome from hypoglycaemia. Despite their unreliability, reagent strip methods continue to be used extensively in neonatal nurseries due to their rapidity and convenience. Recently, a new portable laboratory standard technique has been introduced (HemoCue...

متن کامل

Numerical investigation of GFRP bars contribution on performance of concrete structural elements

In this study, twenty glass fiber reinforced polymer (GFRP) reinforced concrete specimens were modelled using finite element method to predict the effect of GFRP compressive bars on the flexural strength and ductility of GFRP reinforced concrete beams. Also, the contribution of GFRP longitudinal rebars to the load-carrying capacity of reinforced concrete columns is determined. The concrete elas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies

دوره 33 8  شماره 

صفحات  -

تاریخ انتشار 1995