Scanning electron microscopic characteristics of phakic intraocular lenses.
نویسندگان
چکیده
OBJECTIVE To analyze the surface quality of new generation phakic intraocular lenses (IOLs). DESIGN Experimental materials study. MATERIALS Three different new generation phakic IOLs: angle-fixated anterior chamber lens Chiron Vision NuVita MA20 (polymethylmethacrylate [PMMAD, iris-fixated anterior chamber lens Ophtec Artisan Iris-Claw (PMMA), posterior chamber lens Staar ICM (polymer from porcine collagen and 2-hydroxyethyl methacrylate [HEMA]). METHODS Representative samples of three different phakic IOLs underwent surface and edge-finish examination with light microscopy (LM). The phakic IOLs were then examined by use of scanning electron microscopy (SEM), and particular attention was given to optic surface quality, edge finish, haptic, and optic/haptic junction. RESULTS In all IOLs the LM examination showed a smooth and homogeneous surface. No irregularities, particularly at the optic front and back surface, optic edge, haptic, and the optic/haptic junctions, were detected by SEM. One exception was a minor surface roughness at the claws of an Artisan iris-fixated anterior chamber IOL. CONCLUSIONS Phakic IOLs are implanted either in the anterior or posterior chamber of healthy eyes, and high standards for their surface quality are required. The evaluation of surface properties with LM and SEM did not reveal any defects that contraindicate the implantation of phakic IOLs.
منابع مشابه
Material Analysis of Spontaneously Subluxated Iris-Fixated Phakic Intraocular Lenses.
PURPOSE To conduct a material analysis of spontaneously subluxated iris-fixated phakic intraocular lenses (IOLs) using light and scanning electron microscopy. METHODS Six explanted Artisan/Verisyse and Artiflex/Veriflex IOLs (Ophtec, Groningen, Netherlands/AMO, Santa Ana, CA) were analyzed in a laboratory using light and scanning electron microscopy. Four of the IOLs had been explanted after ...
متن کاملBilateral cataract after phakic posterior chamber top hat-style silicone intraocular lens.
BACKGROUND New strategies have been developed for surgical treatment of high myopia. Recently, implantation of minus power posterior chamber intraocular lenses (IOL) into phakic eyes has been introduced. METHODS We report a 37 year-old female patient who developed bilateral anterior subcapsular cataract 7 years after minus-power, top hat-style silicone posterior chamber IOL implantation in Ru...
متن کاملPhakic Intraocular Lenses and their Special Indications
Phakic intraocular lenses revolutionize refractive surgery and continue to serve as an excellent option for vision correction in patients who are not ideal candidates for laser vision correction. This article will review special indications of phakic intraocular lenses in the clinical practice.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmology
دوره 107 5 شماره
صفحات -
تاریخ انتشار 2000