Corrosion Performance of Prestressing Strands in Contact with Dissimilar Grouts

نویسندگان

  • Matthew O’Reilly
  • David Darwin
  • JoAnn Browning
چکیده

To improve the corrosion protection provided to prestressing strands, anti-bleed grouts are used to fill voids in post-tensioning ducts that result from bleeding and shrinkage of older portland cement grouts. Environmental differences caused by exposing the strands to dissimilar grouts, however, have the potential to cause rapid corrosion. Portland cement grout, gypsum grout, and four commercially available prepackaged grouts were analyzed to determine the chemical composition of the resulting pore solutions and tested to determine if using a second grout will provide improved corrosion protection for prestressing strands or result in accelerated corrosion. The potential consequences of leaving the voids unfilled were also evaluated. Pore solutions were analyzed for pH and sodium, potassium, fluoride, chloride, nitrite, sulfate, carbonate, nitrate, and phosphate ion content. The analyses were used to develop simulated pore solutions. Selected grouts and simulated pore solutions were paired to evaluate their potential to cause corrosion of, respectively, grout-wrapped and bare stress-relieved seven-wire prestressing strands using the rapid macrocell test. Strands were also evaluated in simulated pore solutions containing chlorides and in deionized water. Because exposure of strands to water or chlorides has the potential to cause rapid corrosion, filling voids in post-tensioning ducts with an antibleed grout is recommended. Gypsum grout, with its low pH and high sulfate content, will cause accelerated corrosion of strands when used in conjunction with portland cement grout or any of the commercially prepackaged grouts tested. When paired with portland cement grout, the prepackaged anti-bleed grouts evaluated in this study resulted in corrosion losses significantly below those observed for strands exposed to salt or water. The highest corrosion measured for a prepackaged grout occurred for the grout with the highest pore solution sulfate content.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Investigation of Degradation of Mechanical Behaviour of Prestressing Strands Subjected to Chloride Attacking

Corrosion of reinforcing and prestressing steel due to chloride contamination is one of the primary causes of deterioration of concrete structures. A review of published literatures shows that the research on the deterioration of mechanical properties of reinforcing steel is more than that on prestressing strands, even though the corrosion of prestressing strands may trigger structural collapse...

متن کامل

Spatial Variability of Pitting Corrosion and Its Effect on the Strength and Reliability of Prestressed Concrete Bridge Beams

Corrosion of reinforcing and prestressing steel due to chloride attack is one of the major causes of deterioration of concrete structures. This is of most concern because of the associated reduction in steel cross-sectional area, spalling and loss of bond. In the case of prestressed concrete structures, the corrosion of prestressing strands can lead to a sudden failure due to higher stress leve...

متن کامل

Mechanism of Corrosion of Steel Strands in Post Tensioned Grouted Assemblies

In this preliminary study, the complexity of the corrosion phenomenon of post-tensioning strands in grouted anchorage assemblies was examined and both physicochemical and electrochemical key technical issues were identified. Measurements of oxygen reduction efficiency in high pH electrolytes were conducted to obtain polarization parameters to be used in modeling. The time evolution of electrica...

متن کامل

Acoustic Emission use for prestressing strands corrosion assessment

Acoustic emission (AE) is studied to monitor stress corrosion cracking (SCC) of prestressing strands. This nondestructive method seems particularly recommended because it has the capacity to realize a real time and a remote detection of active defects. In this study corrosion mechanisms are generated in an accelerated way. A particular attention has been made on hydrogen embrittlement process b...

متن کامل

2686: Investigation of Stress Corrosion Cracking Susceptibility of High Strength Stainless Steels for Use as Strand Material in Prestressed Concrete Construction in a Marine Environment

Stainless steel reinforcing has an elevated chloride threshold and is an attractive alternative for prestressed concrete applications. However, due to the high strength requirements for prestressing strands, concern exists about the possibility of stress corrosion cracking (SCC). This investigation screened for potential SCC development three candidate high strength alloys for use as prestresse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012