Oxygenator evaluation: Maxima 1380 versus Maxima Plus.

نویسندگان

  • J H Engle
  • J Ploessl
  • R Sutton
چکیده

Continual improvement of oxygenators has been important in the growing demands of patient safety and support during cardiopulmonary bypass. The purpose of this study was to compare the Maxima 1380 oxygenator to the upgraded Maxima Plus oxygenator. Thirty-two adult patients were randomized to either the 1380 group or the Plus group. Information was recorded on the patients' weight, age, body surface area, esophageal temperature, arterial temperature, venous oxygen saturation, arterial pO2, arterial pCO2, blood flow, hematocrit, gas sweep, and FiO2. No significant difference was found between the two groups' mean weight, body surface area, arterial pO2 arterial pCO2, age, esophageal temperature, arterial temperature, venous oxygen saturation, and blood flow (p > 0.05). The Plus group demonstrated significantly lower mean gas sweep rates and FiO2 settings than the 1380 group. FiO2 of the 1380 was dependent on age, body surface area, blood flow, and esophageal temperature (r = 0.89, p < 0.001). FiO2 of the Plus was correlated with weight, esophageal temperature, arterial temperature, and arterial pO2 (r = 0.93, p < 0.001). Gas sweep rate of the 1380 was dependent on age, weight, esophageal temperature, blood flow, arterial temperature, and arterial pCO2 (r = 0.84, p < 0.001). The gas sweep rate of the Plus was dependent on weight and esophageal temperature (r = 0.55, p < 0.001). Based on these analyses, the new Maxima Plus oxygenator is more efficient in oxygen and carbon dioxide transport than the Maxima 1380.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental evaluation of the Medtronic Maxima Forté hollow fiber membrane oxygenator.

A new hollow fiber membrane oxygenator, the Medtronic Maxima Forté, was tested for gas transfer, blood path resistance and blood handling characteristics in a standardized setting with surviving animals. Three calves (mean body weight: 71 +/- 9.6 kg) were placed on cardiopulmonary bypass at a mean flow rate of 50 ml/kg/min for six hours. The circuit included the Maxima Forté oxygenator. The ani...

متن کامل

Evaluation of Antidepressant-like Effect of Citrus Maxima Leaves in Animal Models of Depression

Objective(s) This study planned to assess antidepressant like activity of aqueous extract from leaves of Citrus maxima Merr. (Rutaceae). Materials and Methods Boiling was used for aqueous extraction. Acute toxicity study was performed in mice. Antidepressant activity was studied using locomotor activity test, modified forced swimming test (FST) and tail suspension test (TST). Three doses 100...

متن کامل

Cucurbita maxima (Pumpkin) seeds: Scolicidal activity and preventive efficacy of its extract on experimental hydatidosis in mice

Introduction: Hydatid Disease (HD), a helminth infection with various clinical complications is a serious economic and public health concern around the world. Nowadays, different agents have been broadly applied as scolicids; these agents have several side effects on patients. Therefore, the aims of this experimental study were to evaluate the scolicidal activity of Cucurbita maxima seeds metha...

متن کامل

A NOTE ON THE AVERAGING METHOD FOR DIFFERENTIAL EQUATIONS WITH MAXIMA

Substantiation of the averaging method for differential equations with maxima is presented. Two theorems on substantiates for differential equations with maxima are established.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 1995