Removal of a Broken Cannulated Intramedullary Nail: Review of the Literature and a Case Report of a New Technique

نویسندگان

  • Amr A. Abdelgawad
  • Enes Kanlic
چکیده

Nonunion of long bones fixed with nails may result in implant failure. Removal of a broken intramedullary nail may be a real challenge. Many methods have been described to allow for removal of the broken piece of the nail. In this paper, we are reviewing the different techniques to extract a broken nail, classifying them into different subsets, and describing a new technique that we used to remove a broken tibial nail with narrow canal. Eight different categories of implant removal methods were described, with different methods within each category. This classification is very comprehensive and was never described before. We described a new technique (hook captured in the medulla by flexible nail introduced from the locking hole) which is a valuable technique in cases of nail of a small diameter where other methods cannot be used because of the narrow canal of the nail. Our eight categories for broken nail removal methods simplify the concepts of nail removal and allow the surgeon to better plan for the removal procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removal of a broken intramedullary femoral nail with an unusual pattern of breakage: a case report

To the best of our knowledge, only 3 cases, including the present case, have been reported with a three part broken pattern. However, this is the first case associated with a distal locking screw broken. We report the case of a 31-year-old patient who sustained an open femoral shaft fracture . The fracture was stabilized with a Kuntcher femoral nail. After 7 months of the initial surgery he pre...

متن کامل

Surgical options for broken intramedullary nail.

To the Editor: We would like to compliment Levine et al on their case report “Removal of a Broken Cannulated Tibial Nail: A Simple Intramedullary Technique” (J Orthop Trauma 2004;18:247– 249) and Steinberg et al on their technical trick “Removal of a Broken Distal Closed Section Intramedullary Nail: Report of a Case Using a Simple Method” (J Orthop Trauma 2004;18:233–235). The problem of a brok...

متن کامل

Removal of a Broken Cannulated Femoral Nail: A Novel Retrograde Impaction Technique

This report presents a surgical technique to remove a broken cannulated nail from the femur. A Harrington rod was modified for retrograde impaction of the retained fragment. The broken implant was finally removed without complication. This particular procedure was safe, simple, and promising.

متن کامل

Removal of a broken distal closed section intramedullary nail: report of a case using a simple method.

A simple method to remove a broken distal closed section intramedullary nail is presented. The surgical technique and a case report are described. This technique eliminates the need for an additional exposure, other than that required to insert the nail, or any specialized equipment.

متن کامل

A simple method for removal of the distal segment of a broken femoral intramedullary nail: a case report.

ABSTRACT We report a method for removing the distal segment of a broken locked intramedullary nail secondary to nonunion of the femur following radiotherapy for fibromatosis. A Kirschner wire with one tip fashioned into a hook was used to remove the distal segment without opening with the nonunion site. Details of the procedure are described. KEY WORDS Broken intramedullary nail, removal of d...