Modelling the penumbra in Computed Tomography1
نویسندگان
چکیده
BACKGROUND In computed tomography (CT), the spot geometry is one of the main sources of error in CT images. Since X-rays do not arise from a point source, artefacts are produced. In particular there is a penumbra effect, leading to poorly defined edges within a reconstructed volume. Penumbra models can be simulated given a fixed spot geometry and the known experimental setup. OBJECTIVE This paper proposes to use a penumbra model, derived from Beer's law, both to confirm spot geometry from penumbra data, and to quantify blurring in the image. METHODS Two models for the spot geometry are considered; one consists of a single Gaussian spot, the other is a mixture model consisting of a Gaussian spot together with a larger uniform spot. RESULTS The model consisting of a single Gaussian spot has a poor fit at the boundary. The mixture model (which adds a larger uniform spot) exhibits a much improved fit. The parameters corresponding to the uniform spot are similar across all powers, and further experiments suggest that the uniform spot produces only soft X-rays of relatively low-energy. CONCLUSIONS Thus, the precision of radiographs can be estimated from the penumbra effect in the image. The use of a thin copper filter reduces the size of the effective penumbra.
منابع مشابه
Investigation of physical penumbra definition in treatment planning
Background: Due to the small size of the beamlets in IMRT (intensity modulated radiotherapy), physical penumbra is one of the important dosimetric parameters and small changes in the penumbra have a notable impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating...
متن کاملInvestigation of physical penumbra definition in IMRT applications
Introduction: Because of small size of the beamlets in IMRT, physical penumbra is one of the important dosimetric parameters and small changes in the penumbra will have a great impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating the inconsi...
متن کاملIsolated Iliac Artery Aneurysm
Unlike abdominal and combined aortoiliac artery aneurysms, isolated iliac artery aneurysms (IIAAs) are uncommon. An isolated iliac artery aneurysm is defined as a twofold increase in the diameter of the iliac artery without a coexisting aneurysm at another location. IIAA was encountered infrequently in the past, comprising 0.9% to 4.7% of all intraabdominal aneurysms according to a review of pr...
متن کاملPenumbra Measurements and Comparison of In-House and Standard Circular Cones by the Gafchoromic Film, Pinpoint Ion Chamber, and MCNPX Monte Carlo Simulation
Introduction: Penumbra is an important property of the radiation beam to obtain a suitable margin surrounding the target volume. Therefore, the precise penumbra width determination in stereotactic radiotherapy is necessary for treatment planning. This study aimed to compare the obtained results of penumbra width by in-house and standard circul...
متن کاملThe concept of ischemic penumbra in acute stroke and therapeutic opportunities.
Ischemic penumbra was first defined by Astrup in 1981 as perfused brain tissue at a level within the thresholds of functional impairment and morphological integrity, which has the capacity to recover if perfusion is improved. It exists, even for a short period of time in the center of ischemia, from which irreversible necrosis propagates to the neighboring tissues over time. Penumbra has become...
متن کامل