Pressure sensor calibration for measuring stud-player impacts

نویسندگان

  • Bodil Y. Oudshoorn
  • Heather F. Driscoll
  • Marcus Dunn
  • David James
چکیده

In rugby union, laceration injuries can occur from players stamping on opponents in the ruck. To measure the stud-skin interaction during stamping movements, pressure sensors can be used. Pressure sensor calibration techniques have highlighted the need to perform calibrations using appropriate impact dynamics. A pilot study with seven rugby players informed the expected peak forces and loading rates of rugby stamps. Subsequently, a custom calibration procedure was developed, using a drop hammer and force platform to replicate the experimentally observed forces and loading rates. The conventional calibration of the pressure sensor system, supplied by the manufacturer, overestimated total force by 132%. The method described in this paper resulted in a mean error of 7.5%. This study describes a simple and effective calibration procedure for using pressure sensors when measuring the peak force from stud-player impacts. The method has potential to be used as an improved calibration protocol when the expected peak force range of the measured event is between 1800 and 3000 N. The calibrated pressure sensors will be used to obtain kinetic data from stamping events in the ruck in rugby union. © 2016 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the organizing committee of ISEA 2016

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Optical Measurement System to Measure Velocity and Provide Shock Wave Pressure Diagrams

This paper introduces an optical measurement system for shock wave characteristics. The system works by mountinga metal plate attached to spring mounts against the shock wavefront. This set is sealed and can plot the shock wave pressure diagram by measuring plate's displacement, radiation and changing the reflection of light during shock wave conflict, and converting these optical data to volta...

متن کامل

Chapter 2 : Investigation of Effective Mass Differences for Helmet to Helmet Impacts in Football : Role of the Neck and Implications on Injury

The research presented herein is an analysis of acceleration measurements of the head during helmet-helmet impacts, where a player’s helmet impacts another player’s helmet, and with a youth population in football. This research is aimed at advancing current understanding of impact biomechanics for two specialized groups. The first study is an observational analysis focusing on helmet-helmet imp...

متن کامل

Dynamic Tire Pressure Sensor for Measuring Ground Vibration

This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS), possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration ca...

متن کامل

Influence of Individual Differences on the Calculation Method for FBG-Type Blood Pressure Sensors

In this paper, we propose a blood pressure calculation and associated measurement method that by using a fiber Bragg grating (FBG) sensor. There are several points at which the pulse can be measured on the surface of the human body, and when a FBG sensor located at any of these points, the pulse wave signal can be measured. The measured waveform is similar to the acceleration pulse wave. The pu...

متن کامل

Design & Implementation of Wireless Sensor Node for Measurement of Conducting Liquid

With abundance of water on the earth the fresh water sources are limited. So a need arises to precisely measure this resource in many industrial and commercial places wirelessly. Many measurement techniques for liquid such as float, pressure gauge, ultrasonic and radar are available. Floats and pressure gauge suffer from cumulative error which increases with time whereas ultrasonic and radar gi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016