A Comparison of Functional Outcomes After Metallic and Bioabsorbable Interference Screw Fixations in Arthroscopic ACL Reconstructions.
نویسندگان
چکیده
INTRODUCTION Anterior Cruciate Ligament (ACL) is as one of the most frequently injured ligaments in the modern contact sports scenario. Graft fixations can be achieved during anterior cruciate ligament (ACL) reconstructions by using either bioabsorbable screws or metal screws. The objective of this study was to compare the functional outcomes after bioabsorbable and metallic interference screw fixations in arthroscopic anterior cruciate ligament reconstructions done by using hamstring grafts. MATERIALS AND METHODS This was a prospective, randomized study. Patients in Group 1 received bioabsorbable interference screws and patients in Group 2 received metallic interference screws. Arthroscopic assisted, anterior cruciate ligament reconstructions with the use of hamstring grafts which were fixed proximally with endobuttons and distally with bioabsorbable or metallic interference screws, were undertaken. Progress in functional outcomes was assessed by using Mann Whitney U- test. Functional outcomes in the two groups were compared by using independent t-test. OBSERVATION AND RESULTS In each group, there were statistically significant improvements in functional outcomes over successive follow-ups, which were seen on basis on Mann-Whitney U-test. The comparison of functional outcomes between the two groups, done by using independent t-test, showed no statistically significant differences between the two groups at 3 months, 6 months and 1 year of follow-up. p-value <0.05 was considered to be significant in our study. CONCLUSION In our prospective study of comparison of functional outcomes between bioabsorbable and metallic interference screws in arthroscopic anterior cruciate ligament reconstuctions, which were evaluated by using Tegner activity scale and Lysholm knee scoring scale for a period of 1 year, no statistically significant difference was found. However, further authentication is required by doing long term studies.
منابع مشابه
A comparison of functional outcome between bioabsorbable interference screw and endobutton fixation on femur in arthroscopic anterior cruciate Ligament reconstruction
Introduction: Arthroscopic Anterior Cruciate Ligament [ACL] reconstruction is very commonly done procedure in recent times {1}. The graft fixation methods vary from aperture fixation [Interference screws] to suspensory fixation methods [Endobutton]. This is a Prospective non randomised clinical study of arthroscopic ACL reconstruction comparing the functional results between aperture fixation a...
متن کاملFunctional Outcome Following Arthroscopic ACL Reconstruction with Rigid Fix: A Retrospective Observational Study
Background: No uniform consensus exists to decide type of fixation for arthroscopic anterior cruciate ligament reconstruction. Hypothsis: There is similar functional outcome after rigid fix compared to other methods of fixation which has been published. Study design: Retrospective observational study. Methods: A total of 50 patients underwent arthroscopic anterior cruciate ligament reconstruc...
متن کاملBioabsorbable versus metallic interference screws in anterior cruciate ligament reconstruction: a systematic review of overlapping meta-analyses.
PURPOSE Multiple meta-analyses of randomized controlled trials have been conducted to compare clinical and functional outcomes after anterior cruciate ligament (ACL) reconstruction using metallic interference screw (MIS) versus bioabsorbable interference screw (BIS) fixation, but discrepancies in their findings have prevented a consensus conclusion. The purposes of this study were (1) to conduc...
متن کاملMetallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction?
BACKGROUND Approximately 100,000 anterior cruciate ligament (ACL) reconstructions are performed in the USA each year. Interference screw fixation is considered the standard for rigid fixation of the graft and provides higher fixation strength compared with other devices such as staples or buttons. The present study summarizes the latest evidence comparing the effectiveness of the available clas...
متن کاملBiomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical and diagnostic research : JCDR
دوره 8 4 شماره
صفحات -
تاریخ انتشار 2014