Quantifying ITV instabilities arising from 4DCT: a simulation study using patient data.

نویسندگان

  • Sara St James
  • Pankaj Mishra
  • Fred Hacker
  • Ross I Berbeco
  • John H Lewis
چکیده

Treatment planning for patients undergoing radiation therapy is often performed based on four-dimensional computed tomography (4DCT) when respiratory motion is present, as in lung cancer patients. 4DCT is used to define the internal target volume (ITV) that, ideally, incorporates all potential locations of the tumour. In this work, we use the locations of gold fiducial markers implanted in lung tumours of eight patients to represent tumour motion. These fiducial locations are used in a simulation of a four-slice CT scanner to generate the ITV for 10, 20 and 30 mm diameter model tumours. To demonstrate instabilities in the ITV definition based on 4DCT, the ITV calculation was repeated for the same patients for consecutive scan start times, staggered by 1 s. The volumetric difference in the ITV and the per cent of time that the ITV contains in the tumour are both evaluated. The ITV from a single patient was found to vary by 46%-127% for a tumour diameter of 10 mm. The ITV did not cover the entirety of the tumour 11%-74% of the time for a 10 mm tumour diameter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of irregular breathing patterns on internal target volumes in four-dimensional CT and cone-beam CT images in the context of stereotactic lung radiotherapy.

PURPOSE Stereotactic lung radiotherapy is complicated by tumor motion from patient respiration. Four-dimensional CT (4DCT) imaging is a motion compensation method used in treatment planning to generate a maximum intensity projection (MIP) internal target volume (ITV). Image guided radiotherapy during treatment may involve acquiring a volumetric cone-beam CT (CBCT) image and visually aligning th...

متن کامل

Geometrical differences in gross target volumes between 3DCT and 4DCT imaging in radiotherapy for non-small-cell lung cancer

The aim of this study was to explore the characteristic of 3DCT scanning phases and estimate the comparative amount of respiration motion information included in 3DCT and 4DCT by comparing the volumetric and positional difference between the volumes from 3DCT and 4DCT for the radiotherapy of non-small-cell lung cancer (NSCLC). A total of 28 patients with NSCLC sequentially underwent 3DCT and 4D...

متن کامل

Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer.

PURPOSE Hypofractionated stereotactic radiotherapy (SRT) for Stage I non-small-cell lung cancer requires that meticulous attention be paid toward ensuring optimal target definition. Two computed tomography (CT) scan techniques for defining internal target volumes (ITV) were evaluated. METHODS AND MATERIALS Ten consecutive patients treated with SRT underwent six "standard" rapid multislice CT ...

متن کامل

AbstractID: 10123 Title: Effects of breathing variation on internal target volume (ITV) in respiratory gated radiation therapy

ID: 10123 Title: Effects of breathing variation on internal target volume (ITV) in respiratory gated radiation therapy Introduction: Accuracy of 4DCT reconstruction depends on reproducible patient breathing during scans and highly synchronized external surrogates. Studies have been conducted to investigate the effects of breathing variation on the motion information extracted from 4DCT (1, 2). ...

متن کامل

Comparison of biological target volume metrics based on FDG PET-CT and 4DCT for primary non-small-cell lung cancer

Fluorodeoxyglucose positron emission tomography-computed tomography (PET-CT) and four-dimensional CT (4DCT) are used in several methods for defining the biological target volume (BTV) in primary non-small cell lung cancer (NSCLC). Disagreements between the assessments using these methodologies make the use of BTV for radiotherapy planning controversial. In this study, we compared existing metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 57 5  شماره 

صفحات  -

تاریخ انتشار 2012