Pirfenidone inhibits fibrosis in foreign body reaction after glaucoma drainage device implantation

نویسندگان

  • Kyoung In Jung
  • Chan Kee Park
چکیده

BACKGROUND The aim of this study was to investigate the antiscarring effects of pirfenidone on foreign body reaction in a rabbit model of glaucoma drainage implant surgery. METHODS Adult New Zealand White rabbits had glaucoma drainage device implantation using Model FP8 Ahmed glaucoma valves. One eye was randomly assigned to receive postoperative intrableb injection of pirfenidone followed by topical treatment. The other eye underwent the same procedure but without the addition of pirfenidone. Histochemical staining and immunohistochemistry for blebs were performed. RESULTS The degree of cellularity was smaller in the pirfenidone group than in the control group at 2 weeks post operation (P=0.005). A few foreign body giant cells were detected in the inner border of the capsule, and their numbers were similar in the control and pirfenidone groups (P>0.05). Using Masson's trichrome stain, the inner collagen-rich layer was found to be thinner in the pirfenidone group than the control group at 4 weeks (P=0.031) and 8 weeks (P=0.022) post operation. The percentage of proliferating cell nuclear antigen-positive cells was lower in the pirfenidone group than in the control group at 2 weeks post operation (total bleb, P=0.022; inner bleb, P=0.036). Pirfenidone treatment decreased the immunoreactivity of connective tissue growth factor at 2 weeks post operation (total bleb, P=0.029; inner bleb, P=0.018). The height and area of α-smooth muscle actin expression were lower in the pirfenidone group than the control group at 2 weeks, 4 weeks, and 8 weeks post operation (all P<0.05). CONCLUSION Postoperative intrableb injection of pirfenidone followed by topical administration reduced fibrosis following glaucoma drainage device implantation. These findings suggest that pirfenidone may function as an antiscarring treatment in foreign body reaction after tube-shunt surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Creation of a drug-coated glaucoma drainage device using polymer technology: in vitro and in vivo studies.

OBJECTIVE To create and test a slow-release antifibrotic drug-coated glaucoma drainage device using in vitro and in vivo experiments. METHODS A slow-release device incorporating mitomycin C in poly(2-hydroxyethyl methacrylate) disks was developed using redox-polymerization techniques. A standardized preparation of this drug delivery device was attached to the Ahmed glaucoma valve (model FP7; ...

متن کامل

Suppression of TGF-β pathway by pirfenidone decreases extracellular matrix deposition in ocular fibroblasts in vitro

In glaucoma surgery, fibrotic processes occur, leading to impairment of liquid outflow. Activated fibroblasts are responsible for postoperative scarring. The transforming growth factor-β (TGF-β) pathway plays a key role in fibroblast function, differentiation and proliferation. The aim of this study was the characterization of the fibrotic potential of two subtypes of primary human ocular fibro...

متن کامل

The development of a micro‐shunt made from poly(styrene‐block‐isobutylene‐block‐styrene) to treat glaucoma

Glaucoma is the second leading cause of blindness with ∼70 million people worldwide who are blind from this disease. The currently practiced trabeculectomy surgery, the gold standard treatment used to stop the progression of vision loss, is rather draconian, traumatic to the patient and requires much surgical skill to perform. This article summarizes the more than 10-year development path of a ...

متن کامل

Surgical Complications of Cochlear Implantation

Cochlear implantation is a method used for the treatment of patients with profound hearing loss. This procedure may the accompanied by some major or minor complications. We evaluated the surgical complications of cochlear implantation in Fars province (south of Iran). A total of 150 patients with cochlear implantation were enrolled in the present study. Most of the patients were pre-lingual chi...

متن کامل

Foreign Body Reaction After Cochlear Implantation: A Case Report.

Foreign body reaction is a rare complication after cochlear implantation. When such complications do occur, they may be intractable and difficult to be cured with antibiotics or surgical revision that may lead to cochlear reimplantation finally. In this article, we presented a patient with foreign body reaction who recovered well after cochlear reimplantation and has been in good health through...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016