Hourglass urinary bladder in a spinal cord injury patient - unusual late complication of suprapubic cystostomy: a case report

نویسندگان

  • Subramanian Vaidyanathan
  • Peter L Hughes
  • Bakul M Soni
  • Gurpreet Singh
  • Paul Mansour
چکیده

INTRODUCTION Suprapubic cystostomy is performed in spinal cord injury patients in order to prevent complications associated with long-term urethral catheter drainage. We report a patient in whom suprapubic catheter did not drain urine satisfactorily and imaging studies revealed hourglass bladder. CASE PRESENTATION A female patient sustained paraplegia in a traffic accident in 1994 at the age of seventeen years. When she was discharged from spinal unit, she was performing self- catheterisations. In 1995, indwelling urethral catheter drainage was instituted, as she was not able to cope up with self-catheterisations. Intravenous urography, performed in 1994, 1997, 2000 and 2003 showed urinary bladder of normal shape. In 2004, this patient developed frequent blockages and bypassing of catheter; therefore, suprapubic cystostomy was performed. In 2005, she was leaking urine per urethra; therefore, an indwelling catheter was inserted; both suprapubic and urethral catheters drained urine. In 2008, suprapubic catheter failed to drain any urine. Cystogram revealed hourglass bladder. The balloon of suprapubic Foley catheter was located in the upper compartment of hourglass bladder whereas the urethral catheter was placed in the inferior compartment. Ultrasound examination of urinary bladder showed two compartments of hourglass bladder separated by a narrow waist. Computed tomography cystogram delineated smaller superior and larger inferior compartment of the hourglass bladder. At present this patient is happy to manage her bladder with suprapubic and urethral catheters. CONCLUSION When prompt replacement of a mal-functioning suprapubic catheter fails to rectify the problem, computer tomography cystography should be performed to check precise location of suprapubic catheter and structural abnormalities of urinary bladder. In this patient, cystogram revealed hourglass bladder. Possible reasons for development of hourglass bladder in spinal cord injury patients are: traction applied to dome of urinary bladder by Foley balloon when suprapubic catheter is taped tightly to anterior abdominal wall for several months; uncoordinated contractions of detrusor muscle; chronic cystitis leading to hypertrophy of bladder wall.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preventable long-term complications of suprapubic cystostomy after spinal cord injury: Root cause analysis in a representative case report

BACKGROUND Although complications related to suprapubic cystostomies are well documented, there is scarcity of literature on safety issues involved in long-term care of suprapubic cystostomy in spinal cord injury patients. CASE PRESENTATION A 23-year-old female patient with tetraplegia underwent suprapubic cystostomy. During the next decade, this patient developed several catheter-related com...

متن کامل

Inadvertent positioning of suprapubic catheter in urethra: a serious complication during change of suprapubic cystostomy in a spina bifida patient - a case report

INTRODUCTION Spinal cord injury patients are at risk for developing unusual complications such as autonomic dysreflexia while changing suprapubic cystostomy. We report a male patient with spina bifida in whom the Foley catheter was placed in the urethra during change of suprapubic cystostomy with serious consequences. CASE PRESENTATION A male patient, born in 1972 with spina bifida and parapl...

متن کامل

Fatal Septicaemia Following Suprapubic Cystostomy in a Paraplegic Patient: Never Do a Cystostomy without Prior Urine Culture and Appropriate Antibiogram!

Neuropathic urinary bladder is often colonised by multidrug-resistant bacteria. We report a 64-year-old male spinal cord injury patient with paraplegia, who received gentamicin on empirical basis before undergoing suprapubic cystostomy, as antibiotic sensitivity report of urine was not available. This patient developed fulminate septicaemia. Although appropriate antibiotic therapy (meropenem) w...

متن کامل

Ureteral Rupture Caused by a Suprapubic Catheter in a Male Patient With Spinal Cord Injury: A Case Report

Spinal cord injury (SCI) may lead to urinary system disturbances. Patients with SCI usually have neurogenic bladder, and treatment optionss for this condition include clean intermittent catheterization and a permanent indwelling urethral or suprapubic catheter. Complications of catheterization include urinary tract infection, calculi, urinary tract injury, bladder contraction, bladder spasm, re...

متن کامل

The risk of intra-urethral Foley catheter balloon inflation in spinal cord-injured patients: Lessons learned from a retrospective case series.

BACKGROUND Inflating the balloon of Foley catheter in urethra is a complication of urethral catheterisation. We report five patients in whom this complication occurred because of unskilled catheterisation. Due to lack of awareness, the problem was not recognised promptly and patients came to harm. CASE SERIES A tetraplegic patient developed pain in lower abdomen and became unwell after transu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2009