Transformer Paper Expected Life Estimation Using ANFIS Based on Oil Characteristics and Dissolved Gases (Case Study: Indonesian Transformers)

نویسندگان

  • Rahman Azis Prasojo
  • Harry Gumilang
چکیده

This article presents an algorithm for modelling an Adaptive Neuro Fuzzy Inference System (ANFIS) for power transformer paper conditions in order to estimate the transformer’s expected life. The dielectric characteristics, dissolved gasses, and furfural of 108 running transformers were collected, which were divided into 76 training datasets and another 32 testing datasets. The degree of polymerization (DP) of the transformer paper was predicted using the ANFIS model based on using the dielectric characteristics and dissolved gases as input. These inputs were analyzed, and the best combination was selected, whereas CO + CO2, acidity, interfacial tension, and color were correlated with the paper’s deterioration condition and were chosen as the input variables. The best combination of input variables and membership function was selected to build the optimal ANFIS model, which was then compared and evaluated. The proposed ANFIS model has 89.07% training accuracy and 85.75% testing accuracy and was applied to a transformer paper insulation assessment and an estimation of the expected life of four Indonesian transformers for which furfural data is unavailable. This proposed algorithm can be used as a furfural alternative for the general assessment of transformer paper conditions and the estimation of expected life and provides a helpful assistance for experts in transformer condition assessment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power Transformer Incipient Faults Diagnosis Based on Dissolved Gas Analysis

Incipient fault diagnosis of a power transformer is greatly influenced by the condition assessment of its insulation system oil and/or paper insulation. Dissolved gas-in-oil analysis (DGA) is one of the most powerfull techniques for the detection of incipient fault condition within oil-immersed transformers. The transformer data has been analyzed using key gases, Doernenburg, Roger, IEC and Duv...

متن کامل

A Ni-Doped Carbon Nanotube Sensor for Detecting Oil-Dissolved Gases in Transformers

C2H2, C2H4, and C2H6 are important oil-dissolved gases in power transformers. Detection of the composition and content of oil-dissolved gases in transformers is very significant in the diagnosis and assessment of the state of transformer operations. The commonly used oil-gas analysis methods have many disadvantages, so this paper proposes a Ni-doped carbon nanotube (Ni-CNT) gas sensor to effect...

متن کامل

Application of Physical-Chemical Data in Estimation of Dissolved Gases in Insulating Mineral Oil for Power Transformer Incipient Fault Diagnosis with ANN

In this paper, Artificial Neural Networks are used to solve a complex problem concerning to power transformers and characterized by non-linearity and hard dynamic modeling. The operation conditions and integrity of a power transformer can be detected by analysis of physical-chemical and chromatographic isolating oil, allowing establish procedures for operating and maintaining the equipment. How...

متن کامل

Health Monitoring of Power Transformers by Dissolved Gas Analysis using Regression Method and Study the Effect of Filtration on Oil

Economically transformers constitute one of the largest investments in a Power system. For this reason, transformer condition assessment and management is a high priority task. If a transformer fails, it would have a significant negative impact on revenue and service reliability. Monitoring the state of health of power transformers has traditionally been carried out using laboratory Dissolved G...

متن کامل

New sensor for gases dissolved in transformer oil based on solid oxide fuel cell

Due to the poor anti-jamming performance, less gas species, low detection accuracy, short life, medium leaking or carbonmonoxide poisoning and other defects that current sensors for gases dissolved in transformer oil have, a SOFC-based multi-component gas sensor has been designed. The physical, chemical and electrochemical mechanisms of gases in the SOFC have been analyzed, and the mathematical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017