Bubble CPAP versus CPAP with variable flow in newborns with respiratory distress: a randomized controlled trial.

نویسندگان

  • Ana Cristina Zanon Yagui
  • Luciana Assis Pires Andrade Vale
  • Luciana Branco Haddad
  • Cristiane Prado
  • Felipe Souza Rossi
  • Alice D Agostini Deutsch
  • Celso Moura Rebello
چکیده

OBJECTIVE To evaluate the efficacy and safety of nasal continuous positive airway pressure (NCPAP) using devices with variable flow or bubble continuous positive airway pressure (CPAP) regarding CPAP failure, presence of air leaks, total CPAP and oxygen time, and length of intensive care unit and hospital stay in neonates with moderate respiratory distress (RD) and birth weight (BW) ≥ 1,500 g. METHODS Forty newborns requiring NCPAP were randomized into two study groups: variable flow group (VF) and continuous flow group (CF). The study was conducted between October 2008 and April 2010. Demographic data, CPAP failure, presence of air leaks, and total CPAP and oxygen time were recorded. Categorical outcomes were tested using the chi-square test or the Fisher's exact test. Continuous variables were analyzed using the Mann-Whitney test. The level of significance was set at p < 0.05. RESULTS There were no differences between the groups with regard to demographic data, CPAP failure (21.1 and 20.0% for VF and CF, respectively; p = 1.000), air leak syndrome (10.5 and 5.0%, respectively; p = 0.605), total CPAP time (median: 22.0 h, interquartile range [IQR]: 8.00-31.00 h and median: 22.0 h, IQR: 6.00-32.00 h, respectively; p = 0.822), and total oxygen time (median: 24.00 h, IQR: 7.00-85.00 h and median: 21.00 h, IQR: 9.50-66.75 h, respectively; p = 0.779). CONCLUSION In newborns with BW ≥ 1,500 g and moderate RD, the use of continuous flow NCPAP showed the same benefits as the use of variable flow NCPAP.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Therapeutic Effects of Bubble CPAP and Ventilator CPAP on Respiratory Distress Syndrome in Premature Neonates

Background: Respiratory distress syndrome is one of the main complications associated with low birth weight, and a main cause of mortality in premature neonates. The present study aimed to compare the efficacy of ventilator continuous positive airway pressure (CPAP) and bubble CPAP in the treatment of respiratory distress syndrome (RDS) in premature neonates. Methods: This randomized controlled...

متن کامل

Effect of Bubble and Ventilator-derived Continuous Positive Airway Pressure on the Management of Respiratory Distress Syndrome in Premature Neonates

Background: In this study, we aimed to compare ventilator-derived and bubble continuous positive airway pressure (CPAP) in neonates with respiratory distress syndrome admitted to Neonatal Intensive Care Unit of Vali-e-Asr Hospital, Birjand, Iran, in 2014. Methods: This cohort study was conducted among 68 patients assigned into two groups. The neonates in group A (32 infants) were treated with b...

متن کامل

Sudden Complete Versus Gradual Weaning from Nasal Continuous Positive Airway Pressure in Preterm Neonates: A Randomized Controlled Trial

Background: Continuous positive airway pressure (CPAP) is used as respiratory support in preterm neonates; however, the best weaning method has not yet been determined. In this study, we compared sudden complete and gradual weaning from nasal CPAP (NCPAP) in preterm newborns. Methods: This randomized controlled trial was conducted on 62 prete...

متن کامل

Early Nasal Intermittent Positive Pressure Ventilation (NIPPV) versus Nasal Continuous Positive Airway Pressure (NCPAP) for Respiratory Distress Syndrome (RDS) in Infants of 28-36 weeks gestational age: a Randomized Controlled Trial

Background: Early nasal continuous positive airway pressure (NCPAP) has emerged as a primary modality of respiratory support for preterm infants withrespiratory distress syndrome (RDS). However, 30%-40% of these newborns need subsequent mechanical ventilation. Nasal intermittent positive pressure ventilation (NIPPV) is a promising alternative to NCPAP, especially in po...

متن کامل

High-flow nasal cannula for neonatal respiratory distress: is it enough?

CPAP is the most studied form of noninvasive ventilation in neonates, and early investigations focused on the use of CPAP following surfactant administration, to minimize the need for invasive mechanical ventilation.1 Verder and colleagues demonstrated that a strategy of CPAP following brief intubation and surfactant administration (the INSURE technique: INtubation, SURfactant, Extubation) impr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Jornal de pediatria

دوره 87 6  شماره 

صفحات  -

تاریخ انتشار 2011