Lung ventilation studies with technetium-99m Pseudogas.
نویسندگان
چکیده
Technetium-99m Pseudogas is an ultrafine near monodisperse aerosol of 0.12-microgram diam particle size. This report describes initial clinical experiences with 27 patients referred for investigation of suspected pulmonary embolism, and in whom Pseudogas ventilation images were compared with a high quality commercial aerosol. An additional group of ten patients with severe COPD was examined in a comparative trial of Pseudogas with 81mKr. Pseudogas was better than a conventional aerosol in reaching a diagnosis of pulmonary embolism using a simple blinded comparison with coded images. In addition, bronchial deposition was minimal unless COPD was severe. Moderately well patients had no difficulty inhaling the necessary activity in one or two breaths, and even severely ill and frail aged persons could accomplish the passive breathing maneuver in less than a minute. Clearance of Pseudogas was directly to the systemic circulation with a half-time of 10 min in normal subjects extending up to 100 min in patients with airways disease.
منابع مشابه
Reverse mismatched ventilation-perfusion pulmonary imaging with accumulation of technetium-99m-DTPA in a mucous plug in a main bronchus: a case report.
The phenomenon of reverse mismatched ventilation-perfusion on pulmonary scintigraphy is a fairly common occurrence. We present a patient who was experiencing decreasing oxygen saturation and had a reverse mismatched ventilation-perfusion imaging pattern associated with radiotracer retention in a main bronchus. Technetium-99m-DTPA aerosol lung imaging showed tracer retention in the trachea and r...
متن کاملVentilation-perfusion SPECT/CT in Diagnosing Swyer-James (MacLeod) Syndrome
We present the characteristics of a ventilation-perfusion scan correlating to both planar and single photon emission computed tomography and computed tomography (SPECT/CT) images of the lungs in a patient with SwyerJames (MacLeod) syndrome. A Tc-99m MAA lung perfusion scan was recorded with multiple projections and SPECT/CT. In the ventilation scan, initially dynamic acquisition of aerosol Tc-9...
متن کاملPulmonary deposition of a nebulised aerosol during mechanical ventilation.
BACKGROUND There is increasing use of therapeutic aerosols in patients undergoing mechanical ventilation. Few studies have measured aerosol delivery to the lungs under these conditions with adequate experimental methods. Hence this study was performed to measure pulmonary aerosol deposition and to determine the reproducibility of the method of measurement during mechanical ventilation. METHOD...
متن کاملAerosol delivery with two ventilation modes during mechanical ventilation: a randomized study
BACKGROUND Volume-controlled ventilation has been suggested to optimize lung deposition during nebulization although promoting spontaneous ventilation is targeted to avoid ventilator-induced diaphragmatic dysfunction. Comparing topographic aerosol lung deposition during volume-controlled ventilation and spontaneous ventilation in pressure support has never been performed. The aim of this study ...
متن کاملChanges in regional ventilation and perfusion of the lung after endoscopic laser treatment.
To determine whether endoscopic laser treatment improves both ventilation and perfusion in patients with advanced lung cancer, krypton-81m ventilation and technetium-99m labelled macro-aggregate perfusion scanning was performed immediately before and two or four days after treatment in a consecutive series of 28 patients. Twelve patients had not received any other treatment before laser therapy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 27 6 شماره
صفحات -
تاریخ انتشار 1986