An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance.
نویسندگان
چکیده
OBJECTIVES To evaluate the frequency of unsuspected posterior vessel wall penetration of the internal jugular vein during ultrasound-guided needle cannulation. DESIGN Prospective, single-blinded observational study. SETTING Urban level I emergency department with an annual census of 80,000. PATIENTS Residents who had previously completed a 2-day ultrasound course including a 3-hr didactic and hands-on session on ultrasound-guided central venous cannulation. INTERVENTIONS Residents were asked to place an ultrasound-guided catheter on a human torso mannequin. Residents used a short-axis approach for ultrasound guidance. During the procedure, an 8-4 MHz convex (endocavity) transducer was used to observe the path of the resident's needle without interference with the placement procedure. MEASUREMENTS AND MAIN RESULTS Unknown to residents, researchers tracked the frequency of posterior wall penetration and the final needle location when the resident felt that optimal needle placement was achieved in the lumen of the internal jugular. Residents were also asked to rate their confidence regarding appropriate final needle position on a 10-point Likert scale. Statistical analysis consisted of descriptive statistics and Spearman correlation analysis. A total of 25 residents participated. All had placed at least one ultrasound-guided central catheter previously. The median number of previous ultrasound-guided cannulations was 8.0. Sixteen (64%) residents accidentally penetrated the posterior wall of the internal jugular vein during cannulation. The median number of posterior wall penetrations was 1.0 for all residents. In six cases the final location of the needle was through the posterior wall and deep to the venous lumen. In five of these cases the carotid artery was actually mistakenly penetrated. Median confidence by residents regarding appropriate needle placement was 8.0 out of 10. More training and more ultrasound-guided catheters placed were associated with fewer posterior wall penetrations (p = .04). CONCLUSIONS In this study, residents accidentally penetrated the posterior vessel wall of the internal jugular in a lifelike vascular access mannequin in the majority of cases. These results suggest that care must be taken even with ultrasound-guided central catheter placement and that alternative ultrasound guidance techniques, such as visualization of the vein and needle in longitudinal axis, should be considered.
منابع مشابه
A randomized crossover study comparing a novel needle guidance technology for simulated internal jugular vein cannulation.
BACKGROUND Despite ultrasound guidance for central line placement, complications persist, as exact needle location is often difficult to confirm with standard two-dimension ultrasound. A novel real-time needle guidance technology has recently become available (eZono, Germany) that tracks the needle during insertion. This randomized, blinded, crossover study examined whether this needle guidance...
متن کاملAnatomical variations of the clavicle and main vascular structures in two pediatric patients : subclavicular vein cannulation with supraclavicular approach
Introduction Central venous catheterization (CVC) is implemented for volume resuscitation, hemodynamic monitoring, vasopressor administration, frequent blood sampling, parenteral nutritional support and the administration of long-term chemotherapy [1]. Generally, it is attempted using the internal jugular, subclavian or femoral veins. The subclavian vein access has been the recommended approach...
متن کاملUltrasound guidance for placement of central venous catheters: a meta-analysis of the literature.
OBJECTIVE To evaluate the effect of real-time ultrasound guidance using a regular or Doppler ultrasound technique for placement of central venous catheters. DATA SOURCES We searched for published and unpublished research using MEDLINE, citation review of relevant primary and review articles, conference abstracts, personal files, and contact with expert informants. STUDY SELECTION From a poo...
متن کاملChapter 21. Ultrasound Guidance of Central Vein Catheterization
The multiple indications for central venous catheters (CVCs) include parenteral nutrition, intravascular depletion, access for vasoactive medications, hemodynamic monitoring, cardiopulmonary arrest, difficult peripheral intravenous (IV) access and long-term IV access for medications, such as antibiotics. While these catheters can be life saving, they are also associated with significant risks. ...
متن کاملFourth step for ultrasound-guided central vein catheterization.
Editor—We read with great interest the article by Tokumine and colleagues. The authors have introduced and demonstrated the safest method for central venous catheterization under real-time ultrasound guidance using the long-axis view of the vessel with the in-plane needle approach. As they have pointed out, the ultrasound-guided procedure with the short-axis view of the vessel with the out-of-p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care medicine
دوره 38 1 شماره
صفحات -
تاریخ انتشار 2009