INTRODUCTION Standard radiostereometric analysis of prosthetic migration requires that tantalum beads are inserted into the implant. For manufacturing reasons, this is not possible for humeral head resurfacing implants. We therefore used marker-free radiostereometry, developed for metal-backed acetabular cups, on a dummy model to validate the method for a humeral head resurfacing prosthesis. MATERIAL AND METHODS 3 hemispherical resurfacing prostheses of different sizes were marked with tantalum beads and mounted in a sawbone. Standard and marker-free radiostereometry was then done repeatedly with gradual shifts of position of the prosthesis between each analysis. The marker-free algorithm was then compared to the standard to determine the accuracy. RESULTS The accuracy for marker-free radiostereometry was 0.22-0.47 mm for translations and 0.92-1.56 degrees for rotations. INTERPRETATION Based on our results, marker-free radiostereometry can be used to measure migration of humeral head resurfacing prostheses. This indicates that implant marking is not required when doing radiostereometry on humeral head resurfacing in clinical trials.
منابع مشابه
Measurement of the migration of a focal knee resurfacing implant with radiostereometry
BACKGROUND AND PURPOSE Articular resurfacing metal implants have been developed to treat full-thickness localized articular cartilage defects. Evaluation of the fixation of these devices is mandatory. Standard radiostereometry (RSA) is a validated method for evaluation of prosthetic migration, but it requires that tantalum beads are inserted into the implant. For technical reasons, this is not ...
متن کاملLong-term results and patient satisfaction after shoulder resurfacing.
BACKGROUND Shoulder resurfacing has regained popularity in recent years. This report presents the long-term (>20 years) results of this procedure with regard to patient satisfaction and implant survival. MATERIALS AND METHODS We followed up 61 patients who underwent shoulder resurfacing procedures (74 shoulders) for a minimum of 20 years or until death (7 additional patients were lost to foll...
متن کاملAvascular Necrosis of the Humeral Head: Hemi-Cap, Cap, or Stemmed Solution?
Avascular necrosis of the humeral head, as in other joints, can have a spectrum of severity. The degree of humeral head involvement should dictate the degree of prosthetic replacement required to restore congruity and function. In some very early phases of disease, observation or core decompression and supportive bone grafting may be considered. This article will focus on management of later pr...
متن کاملSurface Replacement: The Hemicap Solution
Partial resurfacing of the humeral head with the Hemicap implant has recently become available. Previously, the use of resurfacing in the glenohumeral joint has been used for the treatment of osteoarthritis, cuff tear arthropathy, rheumatoid arthritis, and avascular necrosis. The technique has provided significant pain relief as well as improved function in all pathologies in the available shor...
متن کاملImplant-Based Prosthetic Reconstruction in Patients with Congenital Ear Defects (Technical Note)
Background and aims: Loss of all or part of the ear is one of the significant defects in the head and neck area (regardless of the cause) that can result from trauma, cancer, congenital diseases, or surgery to remove benign tumors. These defects can be reconstructed with the help of surgical procedures or cosmetic prostheses. However, due to the complex structure of the ear, reconstructive surg...
متن کامل