Evaluation of the Use of Sixth Generation Apex Locators as a Diagnostic Tool to Detect Root Perforations

نویسندگان

  • Vipul Srivastava
  • Neetika Jain
  • Soumyojeet Bagchi
  • Mahendra Pal Singh Negi
چکیده

Aim: The sixth generation apex locators served as an efficient diagnostic tool for detecting root perforations as these are based on the principle of impedance rather than the conventional gradient method. However, their diagnostic accuracy not evaluated well. In the existing study, we assessed and compared the efficacy of two apex locators for diagnostic perspective. Materials and Methods: A total of 32 extracted teeth were perforated and mounted using alginate (Alginate Impression Material, 3M ESPE, USA). Two different apex locators Raypex® 6 Apex Locator (VDW) and ProPex Pixi (Dentsply, USA) were used to detect the intentionally created root perforations (i.e., distance from file tips to external outline of the root surface). The two apex locators measured the same root perforations and compared statistically. Results: The mean distance from file tips to external outline of the root surface was found significantly different and lower (59.9%) in Raypex® 6 Apex Locator as compared to Propex Pixi (mean ± standard deviation: 0.39 ± 0.04 vs. 0.16 ± 0.02, t = 30.57, P < 0.001). Conclusion: We found Raypex® 6 Apex Locator better for root perforations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of electronic apex locators to detect root canal perforations with inserted metallic posts: an ex vivo study

INTRODUCTION The detection of possible root canal perforations caused during a metal post placement is frequently difficult to diagnose. The aim of this study was to investigate the accuracy of apex locators to diagnose such perforations. MATERIALS AND METHODS Thirty mesiolingual root canals of extracted mandibular molars were instrumented (30/.04) and a post space was prepared. A root canal ...

متن کامل

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

The effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants

BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants. METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of the canals was preflared, and the length to the major foramen was ...

متن کامل

مقایسه دقت دستگاه‌های اپکس یاب الکترونیکی ZX Root،Novapex  در مقایسه با رادیوگرافی در شرایط in vivo

Background and Aims: Working length determination and remaining this length is of great importance in root canal therapy. Recently, electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the sensitivity of Root ZX and Novapex electronic apex locators with radiography in a clinical study. Materials and...

متن کامل

In Vitro Detection of Simulated Apical Root Perforation with Two Electronic Apex Locators

INTRODUCTION The aim of this study was to evaluate the accuracy of two electronic apex locators (Smarpex and NovApex) in detecting apical perforation. MATERIALS AND METHODS After access cavity preparations, the working length was determined by the first examiner before and after perforation with a stereomicroscope by introducing a K-file size 10 into the canal and size 25 K-file up to the per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015