Analysis of Antibody Aggregate Content at Extremely High Concentrations Using Sedimentation Velocity with a Novel Interference Optics
نویسندگان
چکیده
Monoclonal antibodies represent the most important group of protein-based biopharmaceuticals. During formulation, manufacturing, or storage, antibodies may suffer post-translational modifications altering their physical and chemical properties. Such induced conformational changes may lead to the formation of aggregates, which can not only reduce their efficiency but also be immunogenic. Therefore, it is essential to monitor the amount of size variants to ensure consistency and quality of pharmaceutical antibodies. In many cases, antibodies are formulated at very high concentrations > 50 g/L, mostly along with high amounts of sugar-based excipients. As a consequence, all routine aggregation analysis methods, such as size-exclusion chromatography, cannot monitor the size distribution at those original conditions, but only after dilution and usually under completely different solvent conditions. In contrast, sedimentation velocity (SV) allows to analyze samples directly in the product formulation, both with limited sample-matrix interactions and minimal dilution. One prerequisite for the analysis of highly concentrated samples is the detection of steep concentration gradients with sufficient resolution: Commercially available ultracentrifuges are not able to resolve such steep interference profiles. With the development of our Advanced Interference Detection Array (AIDA), it has become possible to register interferograms of solutions as highly concentrated as 150 g/L. The other major difficulty encountered at high protein concentrations is the pronounced non-ideal sedimentation behavior resulting from repulsive intermolecular interactions, for which a comprehensive theoretical modelling has not yet been achieved. Here, we report the first SV analysis of highly concentrated antibodies up to 147 g/L employing the unique AIDA ultracentrifuge. By developing a consistent experimental design and data fit approach, we were able to provide a reliable estimation of the minimum content of soluble aggregates in the original formulations of two antibodies. Limitations of the procedure are discussed.
منابع مشابه
Analysis of Protein Aggregation, Stability, and Lot Comparability by Sedimentation Velocity
Sedimentation velocity is a powerful tool for detecting and quantifying aggregates in protein pharmaceuticals and proving comparability of conformation and aggregate content for different manufacturing processes or lots. Recent software techniques, including new approaches developed in our lab, extend the power of the method and make the data easier to interpret. Several examples based on studi...
متن کاملSedimentation velocity, multi-speed method for analyzing polydisperse solutions.
A method is described for the sedimentation velocity analysis of solutions composed of macromolecular solutes of widely disparate size. In sedimentation velocity experiments, usually a single rotor speed is chosen for the entire run, and consequently, the range of observable sedimentation coefficients can be severely limited. This limitation can be removed if the speed is varied during the run,...
متن کاملTools for the Quantitative Analysis of Sedimentation Boundaries Detected by Fluorescence Optical Analytical Ultracentrifugation
Fluorescence optical detection in sedimentation velocity analytical ultracentrifugation allows the study of macromolecules at nanomolar concentrations and below. This has significant promise, for example, for the study of systems of high-affinity protein interactions. Here we describe adaptations of the direct boundary modeling analysis approach implemented in the software SEDFIT that were deve...
متن کاملAnalytical ultracentrifugation for the study of protein association and assembly.
Analytical ultracentrifugation remains pre-eminent among the methods used to study the interactions of macromolecules under physiological conditions. Recent developments in analytical procedures allow the high resolving power of sedimentation velocity methods to be coupled to sedimentation equilibrium approaches and applied to both static and dynamic associations. Improvements in global modelin...
متن کاملHydrodynamic Characterization by Analytical Ultracentrifugation and Dynamic Light Scattering
A laboratory-made sample of the polysaccharide xylinan (acetan) has been further characterized with respect to ( i ) purity, (ii) molar mass and polydispersity, and (iii) gross conformation by a combination of hydrodynamic measurements (sedimentation velocity and equilibrium analytical ultracentrifugation, viscometry, and dynamic light scattering) in aqueous NaCl (I = 0.10 mol. L-'). Sedimentat...
متن کامل