Technetium Tc 99m sestamibi sensitivity in oxyphil cell-dominant parathyroid adenomas.
نویسندگان
چکیده
OBJECTIVE A subset of parathyroid adenomas contains a relative overabundance of oxyphil cells that are capable of greater technetium Tc 99m sestamibi tracer uptake and retention than other cell types. We examined whether the presence of oxyphil cells augments the sensitivity of technetium Tc 99m sestamibi preoperative localization and whether the histologic findings of a lesion could be predicted based on the adenoma mass and serum calcium and parathyroid hormone levels. DESIGN Retrospective, single-blinded comparison of technetium Tc 99m sensitivity rates, lesion mass, and preoperative serum calcium and parathyroid hormone values of patients with chief and mixed cell-dominant adenomas and those with oxyphil-dominant parathyroid adenomas. SETTING Tertiary care university hospital. PATIENTS Sixty-three patients diagnosed as having a parathyroid adenoma. INTERVENTION All patients underwent resection of a parathyroid adenoma following a preoperative technetium Tc 99m sestamibi localization study and serum calcium and parathyroid hormone level analysis. MAIN OUTCOME MEASURE Technetium Tc 99m sensitivity rate. RESULTS The overall technetium Tc 99m sestamibi sensitivity rate was 76.2%. The sensitivity within the chief and mixed cell-dominant (n = 52) and oxyphil cell-dominant groups (n = 11) were 71.2% and 100%, respectively (P = .04). There was no correlation between histologic findings of the lesion and its size or serum calcium and parathyroid hormone levels. CONCLUSIONS Oxyphil cell predominance within an adenoma augments technetium Tc 99m sestamibi scan sensitivity in a statistically significant manner. The use of technetium Tc 99m sestamibi preoperative localization may therefore be differentially greater in patients with these types of lesions.
منابع مشابه
Predictors of an accurate preoperative sestamibi scan for single-gland parathyroid adenomas.
OBJECTIVE To investigate why some patients with single parathyroid adenomas have negative preoperative sestamibi scans. DESIGN Retrospective review. SETTING Tertiary care center. PATIENTS Twenty-one patients with false-negative (FN) scans were compared with 22 patients with true-positive (TP) scans. All patients had single parathyroid adenomas. INTERVENTIONS Neck exploration and removal...
متن کاملEffectiveness of surgeon interpretation of technetium tc 99m sestamibi scans in localizing parathyroid adenomas.
OBJECTIVES To evaluate the ability of surgeons to predict the laterality of parathyroid adenomas from technetium Tc 99m sestamibi scans and compare their results with the radiologic interpretations. DESIGN Retrospective medical record review with single- blinded review of sestamibi scans. SETTING Tertiary care academic medical center PATIENTS The study population included 110 consecutive ...
متن کاملDouble-phase Technetium 99m Sestamibi Scintigraphy for the Localization of Parathyroid Adenoma
Objective: The purpose of the present study was to evaluate the accuracy of double phase Tc sestamibi scintigraphy in the assessment of parathyroid glands in patients with hyperparathyroidism and to compare this method with the high-resolution ultrasonography. Methods: From August-1998 through August-2000, we performed Tc -MIBI scintigraphy (MIBI) and neck ultrasonography in 35 patients who wer...
متن کاملDetection of ectopic parathyroid adenoma by early Tc-99m sestamibi imaging.
Localization of Tc-99m sestamibi (MIBI) by parathyroid adenomas (PA) is well known. Typically the radionuclide washes out slowly from the PAs located in the neck. Rapid washout from some PAs has been reported. Various hypotheses have been postulated for slow and rapid clearance of MIBI from PAs, located in the neck. However, the washout of MIBI from ectopic parathyroid adenoma (EPA) in not well...
متن کاملPreoperative technetium Tc 99m sestamibi SPECT imaging in the management of primary hyperparathyroidism in patients with concomitant multinodular goiter.
HYPOTHESIS Preoperative parathyroid and thyroid imaging using technetium Tc 99m sestamibi scintigraphy-single-photon emission computed tomography (Tc 99m MIBI SPECT) and technetium Tc 99m sodium pertechnetate, respectively, in patients with parathyroid adenomas and concomitant multinodular goiters enables the selection of those suitable for minimally invasive radio-guided surgery. DESIGN One ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of otolaryngology--head & neck surgery
دوره 132 7 شماره
صفحات -
تاریخ انتشار 2006