Fluids and microbial penetration in the internal part of cement-retained versus screw-retained implant-abutment connections.
نویسندگان
چکیده
BACKGROUND It has been recently observed that in implants with screw-retained abutments, in in vitro as well as in vivo conditions, bacteria can penetrate inside the internal cavity of the implant as a consequence of leakage at the implant-abutment interface. An alternative to screw-retained abutments is represented by implants that can receive cemented abutments. In this case, the abutment goes through a transmucosal friction implant extension (collar) and is cemented inside the internal hexagonal portion of the implant. The aim of the present research was to compare fluids and bacterial penetration in 2 different implant systems, one with cement-retained abutments (CRA) and the other with screw-retained abutments (SRA). METHODS Twelve CRA dental implants and 12 SRA implants were used in this study. The research was done in 3 steps: scanning electron microscopic (SEM) analysis, fluid penetration analysis, and bacterial penetration analysis. RESULTS 1) Under SEM it was possible to observe in the SRA implants a mean 2 to 7 micron gap between implant and abutment, while in the CRA implants, the gap was 7 micron. In the latter group, however, the gap was always completely filled by the fixation cement. All the spaces between abutment and implant were filled by the cement. 2) With SRA implants, it was possible to observe the presence of toluidine blue at the level of the fixture-abutment interface and the internal threads; the absorbent paper was stained in all cases. With CRA implants, the absorbent paper inside the hollow portion of the implants was never stained by toluidine blue. No penetration of toluidine blue was observed at the implant-abutment interface and inside the hollow portion of the implants. 3) In all the SRA implant assemblies, bacterial penetration was observed at the implant-abutment interface. No bacteria were detected in the hollow portion of the CRA implants. CONCLUSION On the basis of the results obtained in the present study using 2 different implant systems, we conclude that CRA implants offer better results relating to fluid and bacterial permeability compared to SRA implants.
منابع مشابه
Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns.
The mechanical performance of cemented or screw-retained implant-supported crowns with an internal or external configuration is yet to be understood. This in vitro study evaluated the effect of screw-retained and cement-retained prostheses on internal and external implant-abutment connections. Thereby, the reliability and failure modes of crowns were investigated. Eighty-four implants (Emfils; ...
متن کاملA 16-year study of the microgap between 272 human titanium implants and their abutments.
A microgap has been described at the level of the implant-abutment connection. This microgap can be colonized by bacteria, and this fact could have relevance on the remodeling of the peri-implant crestal bone and on the long-term health of the peri-implant tissues. The authors report on 272 implants with screw- or cement-retained abutments retrieved from humans for different causes during a 16-...
متن کاملCement- and screw-retained implant-supported prostheses: up to 10 years of follow-up of a new design.
PURPOSE This retrospective study investigated treatment outcomes over 10 years of a new prosthesis design in implant prosthodontics that uses a combined cement- and screw-retained principle. MATERIALS AND METHODS The clinical data of 78 implant-supported prostheses were examined. Each prosthesis incorporated at least 1 screw-retained element and 1 or more cement-retained telescopic units. One...
متن کاملAn alternative direct technique for the fabrication of an implant-supported, screw-retained fixed interim restoration.
The Journal of Prosthetic Dentistry Yilmaz et al Lautensack et al 7. Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants 2003;18:719-28. 8. Okamoto M, Minagi S. Technique for removing a cemented superstructure from an implant abutment. J Prosthet Dent 2002;87:241-2. 9. Chee WW, Torbati A, Albouy JP....
متن کاملComparative study on stress distribution around internal tapered connection implants according to fit of cement- and screw-retained prostheses
PURPOSE The aim of this study was to compare the passivity of implant superstructures by assessing the strain development around the internal tapered connection implants with strain gauges. MATERIALS AND METHODS A polyurethane resin block in which two implants were embedded served as a measurement model. Two groups of implant restorations utilized cement-retained design and internal surface o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of periodontology
دوره 72 9 شماره
صفحات -
تاریخ انتشار 2001