Contraceptive efficacy of a novel intrauterine device (IUD) in white-tailed deer.

نویسندگان

  • Karl D Malcolm
  • Timothy R Van Deelen
  • David Drake
  • Darrel J Kesler
  • Kurt C Vercauteren
چکیده

Overabundant white-tailed deer (Odocoileus virginianus) pose risks to property, health, and safety of human beings. Public concerns about lethal management can impair efforts to address these issues, particularly in urban settings. Several techniques developed for reducing reproductive output of deer have limited utility because they require repeated dosing to achieve permanent effect and face uncertain regulatory approval for use beyond experimentation. From 10 August 2006 through 30 December 2007, we evaluated the contraceptive efficacy of copper-containing intrauterine devices (IUDs) implanted trans-cervically in white-tailed deer at the E.S. George Reserve in Pinckney, Michigan. Intrauterine devices were implanted before (n=9) and shortly after (n=10) the breeding season. Post-breeding season IUD treatment was in conjunction with a 5cm(3) dose of 5mg/ml prostaglandin F(2alpha) (PGF(2alpha)), delivered subcutaneously. Intrauterine devices reduced pregnancy rates when administered prior to breeding (P<0.001) and prevented pregnancy for up to 2 years (the duration of the study). Two of 8 does that received IUDs prior to the breeding season and survived to the end of the study became pregnant (due to loss of the implant) during the second year while all (n=16) does without implants conceived. Cervical changes associated with early pregnancy made trans-cervical implantation after the breeding season challenging, and resulted in improperly placed IUDs in 2 treated does. The apparent expulsion of IUDs by pregnant does that received the combined treatment after breeding suggests IUD treatment should be limited to the pre-breeding season. Intrauterine devices show potential as a tool for small-scale deer population management via non-steroidal reproductive inhibition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

The single-shot GnRH immunocontraceptive vaccine (GonaCon) in white-tailed deer: comparison of several GnRH preparations.

PROBLEM An effective, single-injection, multi-year, GnRH contraceptive agent is needed to control reproduction in overabundant white-tailed deer populations. METHOD OF STUDY Two GnRH conjugates, GonaCon (GnRH-KLH) and GonaCon-B (GnRH-blue protein), were prepared in emulsion form as one-injection and two-injection immunocontraceptive vaccine formulations. In addition, the GnRH-KLH protein conj...

متن کامل

Lack of association between CU T-380A intrauterine device and secondary infertility in Iran

Objective The appropriate choice of a contraceptive method has been a major issue in reproductive health research. Cu T intrauterine device (Cu T IUD) has been introduced as one of the most effective contraceptive methods in the world, however, the relationship between prior use of Cu T IUD and secondary infertility has not been evaluated in Iran. To examine the association of Cu T-380A IUD and...

متن کامل

Side effects of Intrauterine Device in Breast and Bottle Feeding Mothers

Dear Editor, Implementing health and family planning programs is the most effective way for birth control. Intrauterine device (IUD) is an effective long-acting contraceptive mean.1 Considering little side effects and good compatibility of IUD to physiologic hormonal alterations occurring during breast feeding, the device is an acceptable contraceptive mean in nursing mothers.2In spite of its a...

متن کامل

Partial and complete expulsion of the Multiload 375 IUD and the levonorgestrel-releasing IUD after correct insertion.

OBJECTIVE The contraceptive efficacy of intrauterine devices (IUD) is thought to relate to the position of the IUD in the uterine cavity. Several trials examined the number of copper IUD expulsions, but none evaluated the partial and complete expulsion rate of the levonorgestrel-releasing device (LNG-IUD). STUDY DESIGN This retrospective cohort study compares the dislocation rate of the Multi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Animal reproduction science

دوره 117 3-4  شماره 

صفحات  -

تاریخ انتشار 2010