Signal and noise characteristics of Hahn SE and GE BOLD fMRI at 7 T in humans.
نویسندگان
چکیده
At very high magnetic fields, GE BOLD fMRI is expected to contain nonspecific contributions and behave differently than HSE fMRI data. Similarly, the two approaches can conceivably suffer from different contributions to temporal instabilities in a times series that ultimately determine the contrast-to-noise ratio (CNR). We investigate the signal and signal fluctuation characteristics in GE and HSE fMRI data with the imaging parameters separately optimized for each contrast at 7 T. In HSE fMRI, activation-induced fractional signal change (DeltaS/S) decreased rapidly, and the ratio of standard deviations of image-to-image fluctuations due to physiological processes (sigmaPhys) to thermal noise (sigmaTherm) remained constant with increasing voxel volume. In contrast, DeltaS/S as well as volume of activated voxels was virtually independent of voxel size for GE BOLD, and sigma(Phys)/sigmaTherm increased with increasing voxel size. The ratio of BOLD signal changes (GE/HSE) was much closer to 1 in tissue areas compared to vessel areas. These observations led to the conclusions that the spatial extent of the activation-induced DeltaS/S was much broader in the GE data, and that the physiological processes that give rise to the temporal fluctuations lost coherence over millimeter distances in HSE compared to GE fMRI data. While further studies are needed to characterize it fully, sigmaPhys in HSE data was clearly different than in GE data. It was concluded that HSE imaging yields a significantly reduced amount of nonspecific signals compared to GE imaging, and, would be the method of choice (over GE) for high-resolution applications in humans.
منابع مشابه
Evaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies
Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملBOLD Specificity and Dynamics Evaluated in Humans at 7 T: Comparing Gradient-Echo and Spin-Echo Hemodynamic Responses
High-field gradient-echo (GE) BOLD fMRI enables very high resolution imaging, and has great potential for detailed investigations of brain function. However, as spatial resolution increases, confounds due to signal from non-capillary vessels increasingly impact the fidelity of GE BOLD fMRI signals. Here we report on an assessment of the microvascular weighting of the GE BOLD response across the...
متن کاملSpin Echo Hemodynamic Impulse Response at 7 T
Introduction Understanding the mechanism of neurovascular coupling underlying the BOLD fMRI signal is contingent on the accurate spatial and temporal characterization of the hemodynamic impulse response (HIR), linked specifically to the microvasculature (capillary bed). At high field strength (≥7T), the gradient-echo (GE) HIR can differ across cortical depth [1,2], suggesting that voxels deeper...
متن کاملComparison of the location and extent of BOLD activation in high spatial resolution SE and GE fMRI of the Motor Cortex at 7T
Introduction: fMRI studies generally employ gradient-echo (GE) BOLD contrast due to the limited signal change and signal-to-noise ratio (SNR) of spin echo (SE) BOLD contrast at standard field strength. Ultra-high field (7T) provides increased BOLD contrast-to-noise ratio (CNR) and decreases the contribution that large vessels make to GE BOLD contrast, due to higher capillary contribution and th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 24 3 شماره
صفحات -
تاریخ انتشار 2005