Analysis and Optimization of Ventilation Mode of Smoke Control System in Subway Station Fires

نویسندگان

  • RU ZHOU
  • WEI ZHANG
چکیده

In the subway station fires, the most immediate threat to passengers’ life is not the direct exposure to fire, but the smoke inhalation because it contains hot air and toxic gases. Theoretical analysis and CFD simulations are applied to analyze the various possible ventilation model and obtain the optimization of ventilation mode in the subway station fires. According to the structure characters of the subway station and the mechanics analysis of smoke flowing, the air curtain is put forward to control the smoke diffusion according to the streamline and flux principle. The computational mathematical model of the air curtain is derived theoretically. The results indicate that more than 6 minutes for safe evacuation can be guaranteed by air curtain. The quantity of fresh air that the air curtain needs has been only 2/5 of which the traditional method, which effectively prevent the fire expand and control the smoke diffusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of Metro Train Fire in an Underground Station of Tehran Metro Line 7

In this research a fire scenario was simulated in one of the stations of the line 7 of Tehran's subway system. The Line 7 is under construction and the ventilation system is under design. Fire was set for a stopping metro train at the platform of the station. A 160 meter length eight-car metro train with the forth wagon on the fire was studied. The heat release rate is based on a quadratic f...

متن کامل

CFD simulation and optimization of the ventilation for subway side-platform

To obtain the velocity and temperature field of subway station and the optimized ventilation mode of subway side-platform station, this paper takes the evaluation and optimization of the ventilation for subway side-platform station as main line, builds three dimensional models of original and optimization design of the existed and rebuilt station. And using the two-equation turbulence model as ...

متن کامل

ارزیابی ریسک حریق در ایستگاه‌های خط 1 مترو شهر تهران)پست ‌یکسوساز( با روش تجزیه و تحلیل درخت خطا

  Background and a ims: Subway system including infrastructure systems in the transportation industry can potentially exposed to fire, flood, earthquake and similar events and could create catastrophic losses to society. Therefore, this study aims to assess the risk of fire in Tehran subway stations (line 1).   Methods: Inperforming this research, after the identifying the fire hazard resources...

متن کامل

ارزیابی ریسک حریق مقاومت‌های سقفی قطارهای با جریان یکنواخت در مترو شهر تهران با روش درخت تجزیه و تحلیل خطا

Background: Incident of fire within or outside the metro rail trains happened because of a number of reasons that cause catastrophic losses and shock to the community. This study aimed to assess the risk of fire in DC trains and subway lines in Tehran. Methods: For performing this research, after identification of fire hazards in metro trains through observation, interview techniques and revi...

متن کامل

Potentiometric of the Renewable Hybrid System for Electrification of Gorgor Station

In this paper, an optimal design of the renewable combustion plant has been investigated with the aim of ensuring the required load on the Gorgor station. The purpose of this study is to minimize the cost of the proposed hybrid unit during the period of operation of the designed system simultaneously. Information on the intensity of solar radiation and the intensity of wind blowing in the area ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012