Multi-detector row CT angiography with direct intra-arterial contrast injection for the evaluation of neurovascular disease: technique, applications, and initial experience.
نویسندگان
چکیده
The purpose of this study was to evaluate the usefulness of 64-section multi-detector row CT angiography (CTA) with direct intra-arterial contrast injection (IA-CTA) for the evaluation of neurovascular disease. This technique was used in 11 patients at our institution. All studies were technically successful, and there were no complications. Small vascular malformations were mapped easily on high-resolution IA-CTA images, enabling microsurgical resection or stereotactic radiosurgery. In a similar fashion, additional morphologic features were revealed on IA-CTA images not seen on standard 2D and 3D digital subtraction angiography. Of 11 patients undergoing IA-CTA, 7 patients had further anatomic clarity of the small arteriovenous fistula/malformation and 4 patients had changes in the treatment plan on the basis of the IA-CTA findings.
منابع مشابه
مقایسه یافتههای آنژیوگرافی عروق کلیوی به روش توموگرافی کامپیوتری چندلایه با یافتههای جراحی در افراد زنده دهنده کلیه
Background: In kidney transplantation decision about the proper kidney donation is different between surgeons, but simple vasculature anatomy and a kidney without abnormalities are the most important reasons of choosing a kidney. Therefore complete assessment of renal vessels of a live donor with noninvasive techniques is a necessity for nephrectomy. For delineation of the kidney vasculature...
متن کاملMulti-detector row CT angiography in the assessment of carotid artery disease in symptomatic patients: comparison with rotational angiography and digital subtraction angiography.
BACKGROUND AND PURPOSE Compared with the single-detector technique, multi-detector row CT angiography permits larger anatomic coverage that includes both the epiaortic and entire carotid circulations. We evaluated the accuracy of multi-detector row CT angiography by using multiplanar reformation (MPR) for measuring carotid artery diameters compared with that of rotational angiography. We also e...
متن کاملAnterior spinal artery and artery of Adamkiewicz detected by using multi-detector row CT.
BACKGROUND AND PURPOSE Our purpose was to evaluate the visualization of the artery of Adamkiewicz (AKA) and the anterior spinal artery (ASA) by using multi-detector row CT. Preoperative detection of the AKA and ASA is important for prevention of ischemic complications of thoracoabdominal aortic surgery. METHODS Data from contrast-enhanced CT of the abdomen of 19 consecutive patients with know...
متن کاملIntra-arterial and intravenous applications of Iosimenol 340 injection, a new non-ionic, dimeric, iso-osmolar radiographic contrast medium: phase 2 experience
BACKGROUND Iosimenol 340 injection is a new, dimeric, iso-osmolar, iodinated contrast medium for X-ray angiography. PURPOSE To compare the safety and efficacy of iosimenol injection to iodixanol injection in two randomized, controlled phase 2 trials. MATERIAL AND METHODS One hundred and forty-four adult patients were enrolled in the two trials, one for evaluation during arteriography and th...
متن کاملPreoperative visualization of the artery of Adamkiewicz by intra-arterial CT angiography.
BACKGROUND AND PURPOSE CT and MR angiographies have been reported to visualize the artery of Adamkiewicz (AKA) noninvasively to prevent spinal cord ischemia in surgery of thoracic descending aortic aneurysms. The purpose of this work was to compare the usefulness of CT angiography (CTA) with intra-arterial contrast injection (IACTA) with that of conventional CTA with intravenous contrast inject...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 30 5 شماره
صفحات -
تاریخ انتشار 2009