Preconcentration of bismuth(III) and copper(II) by solid-phase extraction and subsequent determination by differential pulse polarography.

نویسندگان

  • A Bhalotra
  • B K Puri
چکیده

A differential pulse polarographic method is proposed for the trace determination of bismuth and copper from large volumes of aqueous samples after adsorption of their 1-(2-thiazolylazo)-2-naphthol complexes onto microcrystalline naphthalene in the pH ranges of 7.2-9.0 and 4.0-7.8, respectively. Bismuth and copper are desorbed from microcrystalline naphthalene with 9 mL 1M HCl. Well-defined peaks are obtained at Ep = -0.09 and -0.20 V versus a saturated calomel electrode, in an HCl-isoquinoline medium as the supporting electrolyte, for bismuth and copper, respectively. Bismuth is reduced reversibly with a 3-electron change, whereas copper is reduced irreversibly under these conditions. The detection limits are 55 ng/mL for bismuth and 91 ng/mL for copper. Linearity is maintained in the concentration ranges of 0.18-13.5 and 0.30-17.3 microg/mL for bismuth and copper, respectively, with corresponding correlation coefficients of 0.9996 and 0.9885. The relative standard deviations are 1.0% for bismuth at 2.0 microg/mL and 1.4% for copper at 5.0 microg/mL. Various parameters were optimized to develop conditions for the determination of these metal ions in various samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Determination of Trace-Bismuth by Extraction-Differential Pulse Polarography in Non-Aqueous Media

The voltammetric characteristics of bismuth(III)-oxinate in chloroform at the mercury electrode were investigated and a quasi-reversible behavior for Bi(III) oxinate reduction was confirmed. Preceded by the extraction of Bi(III) oxinate in chloroform, differential pulse polarography was developed in the extracts for determination of the trace-bismuth. The linear range of the calibration gra...

متن کامل

COLUMN PRECONCENTRATION OF URANIUM BY 1 -(2-PY RIDYLAZ0)-2-NAPHTHOL SUPPORTED ON NAPHTHALENE USING DIF'FERENTLAL PULSE POLAROGRAPHY

A solid chelating material, 1-(2-pyridy1azo)-2-naphthol (PAN) supported on naphthalene provides a rapid and highly selective means of preconcentration of uranium from aqueous solution. Uranium is quantitatively retained on this adsorbent in the pH range 9.8-10.7 with a flow rate of 1 ml min . The metal complex was desorbed with 10 ml of 2 M hydrochloric acid and uranium is determined by d...

متن کامل

Differential Pulse Polarographic Determination of Trace Antimony in Standard Biological Samples after Preconcentration Using 2-Nitroso-1-naphthol-4-sulfonic Acid

A highly selective, sensitive, rapid and economical differential pulse polarographic method has been developed for the determination of trace amounts of antimony in various standard alloys and biological samples after adsorption of its 2-nitroso-1-naphthol-4-sulfonic acid - tetradecyldimethylbenzylammonium chloride on microcrystalline naphthalene in the pH range of 7.5-11.0. After filtratio...

متن کامل

Solid-phase Extraction Using Modified Carbon Nanotube and Cupferron Ligand for Preconcentration and Determination of Trace Amounts of Copper in Real Samples

A solid phase extraction procedure for simultaneous separation and preconcentration of traceamounts of Cu+2 ion from various real samples prior to its determination by flame atomicabsorption spectrometry has been developed. The proposed method is based on the utilization ofmultiwalled carbon nanotube in combination with Cupferron ligand as a solid phaseextractant. The influences of the analytic...

متن کامل

Solid phase extraction of trace cobalt (II) in industrial wastewaters by modified nanotube carbon carboxyl and its determination with flame atomic spectroscopy

Applying a simple and selective sample preparation procedure prior to instrumental analysis is the most important and crucial step in an analytical process. Up to now, various sample preparation techniques based on solid phase extraction (SPE) systems have been developed to isolate various types of analytes from different matrices. In the method presented for preconcentration and measurement of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 84 1  شماره 

صفحات  -

تاریخ انتشار 2001