Airflow obstruction and roadside breath alcohol testing.
نویسندگان
چکیده
FIGURE 1. Bar graph shoiwing distribution oil FVC in study population. Heavily shaded sections represent the three subjects who could not dot the test. Lightly shaded sections represent asthmatic patients. Clear sections represent COPD patients. communications to the editor Communications for this section will be published as space and priorities permit. The comments should not exceed 350 words in length, with a maximum office references; one figure or table can be printed. Exceptions may occur under particular circumstances. Contributions may include comments on articles published in this periodical, or they nuzy be reports of unique educational character. Specc flc permission to publish should be cited in a covering letter or appended as a postscript. We have frequently been asked to give a medicolegal opinion regarding claims of inability' to provide an adequate breath sample to activate a portable roadside breath alcohol testing device because of asthma or chronic obstructive pulmonary disease (COPD). We examined the physical characteristics of a commonly used hand-held breath alcohol screening device (ALERT, model J3A; Alcohol Countermeasures, Mississauga, Ont) and evaluated the ability of patients with asthma or COPD to perform an acceptable test. The roadside testing device we used measures ethanoA in exhaled gas; this reflects the blood alcohol level. It uses a disposable mouthpiece with orifice diameters ofapproximately 3.3 mm, and it has an oiutflow orifice oif approximately 1.2 mm. It has a series of colored lights on the tipper surface. The operational light indicates that the machine is ready to receive the exhaled sample. If an adequate flow of exhaled air passes across the inflow orifice over an adequate length of time, the operational light is replaced by a red, amber, or green light, indicating " fail, " " warn:' oir " pass:' respec-tivell ; regarding alcohol level. If critical flow is not maintained for the lull time, no result is given. If a subject cannot provide an adequate sample in several attempts, he may be charged with " failure to provide a sample. " We connected the testing device N U M B E R 0 F S U B J E C T S through a pressure transducer and flowmeter tot a soiurce oil air. Ve found that at ambient room air temperature and pressure a critical flow of 6.6 Ijmin (1 10 ml/s) sustained loir a period of 5.5 s at a critical pressure of 15 to 17 cm H2O …
منابع مشابه
Evidenzer – A New Breath-Alcohol Analyzer For Evidential Testing
Background Between 1989 and 2002 the only approved instrument for evidential breath-alcohol testing (EBT) in Sweden was Intoxilyzer 5000S (1). During this time about 160,000 EBTs were performed with 150 Intoxilyzer instruments located throughout the country (1,2). When a new generation of EBTs was being considered the police authorities desired that the instrument should be functional both at a...
متن کاملReducing the global burden of hazardous alcohol use: a comparative cost-effectiveness analysis.
OBJECTIVE Intervention strategies are available for reducing the high global burden of hazardous alcohol use as a risk factor for disease, but little is known about their potential costs and effects at a population level. This study set out to estimate these costs and effects. METHOD Analyses were carried out for 12 epidemiological World Health Organization subregions of the world. A populati...
متن کاملBreath sounds in the clinical assessment of airflow obstruction.
In a group of 34 inpatients showing varying degrees of airflow obstruction we studied the relationship between breath sound intensity (BSI) and abnormalities of lung function. The BSI was evaluated by chest auscultation to provide a score, in a manner similar to that described by Pardee et al. (1976), and was found to correlate closely with indices of airflow obstruction of their logarithms suc...
متن کاملThe Reliability and Performance of Breath A Icohol Instruments in the Laboratory and in the Field
The reliability and usefulness o f any breath alcohol instrument for forensic purposes can only be fully assessed from large scale field studies, i.e. under the conditions where it is to be eventually used by the police. As a first approach, however, controlled laboratory trials are necessary for detecting possible limitations o f the device and for setting up specifications regarding the preci...
متن کاملMulti-breath and single breath helium dilution lung volumes as a test of airway obstruction.
Total lung capacity (TLC) and residual volume (RV) measurements derived from multi-breath and single breath helium dilution methods were combined to produce four indices of gas mixing: single breath volume/multi-breath volume ratio (TLCr, RVr) or multi-breath volume minus single breath volume difference (TLCd, RVd). The reproducibility of these indices and their sensitivity and specificity in d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 100 2 شماره
صفحات -
تاریخ انتشار 1991