On The Processing Of The Recorded Data For The SF6 Circuit Breakers From The Transformation Substation 110/20/6kV Craiova South

نویسندگان

  • Maria D. Brojboiu
  • Virginia Ivanov
  • Andrei Savescu
چکیده

The assurance of the reliability for the transformation substations is one of primary goals of the manufacturers and distributors of electricity. Therefore, a proper monitoring and maintenance program is required. The circuit breaker is a complex device, subject to the thermal and mechanical stresses during the normal or fault currents switching. The substations are frequently equipped with SF6 circuit breaker. The circuit breaker components subjected to the thermal stresses are the main contacts which suffer electrical erosion and the nozzle which is subjected to the ablation process. The ablation process appears because of the energy radiation which is transferred from the electric arc. As a result of the ablation, the nozzle geometry, the gas pressure and the electric withstand are changed. Based on the recorded data from the transformation substation 110/20/6kV Craiova South, the mass loss from nozzle, the admissible number of disconnections and the throat nozzle diameter are computed. The graphical representations highlight the impact of the interrupted current, of the arcing time and of the integral I2t over the mentioned ones. Consequently, if the switching process and the time arc value are controlled, the thermal wear can be limited and the equipments users may provide a maintenance program with minimal costs and an increasing of the lifetime.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating Characteristics of N2, CO2 and CF3I in Contrast to High Current Arcs in Circuit Breakers to Choose a Suitable Substitute for SF6

Specific and sensitive operation of circuit breakers makes an individual position for them in power networks. Circuit breakers are at the central gravity of variations and execution operations. Therefore, an optimum operation is the main reason to investigate about new gases to be used in MV and HV circuit breakers instead of SF6. The arc process has enormous complexity because of hydrodynamic ...

متن کامل

Analysis of Electric Field and Polarization of SF6 Circuit Breaker to Approach a Suitable Structure

Abstract: The application of electric field theory to widely different aspects of electrical insulation has led to more understanding the phenomena. Electric fields may be considered as the main reason for insulation failure. The purpose of this paper is to modify importance of analyzing electric field in insulation design. The SF6 circuit breaker is chosen as case study that encounters cri...

متن کامل

Assessing Circuit Breaker’s Electrical Contact Condition through Dynamic Resistance Signature Using Fuzzy Classifier

Circuit Breakers (CBs) are critical components in power system for reliability and protection. To assure their accurate performance, a comprehensive condition assessment is of an imminent importance. Based on dynamic resistance measurement (DRM), this paper discusses a simple yet effective fuzzy approach for evaluating CB’s electrical contacts condition. According to 300 test results obta...

متن کامل

CDM in Sub-Stations by Replacement of SF6 Gas in Circuit Breaker

This paper gives a case of large Sub-Station Clean Development Mechanism (CDM) Project to analyze CDM project’s influence on India’s Sustainable Development. SF6 gas is being extensively used in circuit breakers. SF6 gas has the highest Global warming potential which is 23900 times of Carbon Dioxide. Extensive Survey of SubStation using SF6 circuit breaker has been done in a sample state of Ind...

متن کامل

Reliability Based Optimal Preventive Maintenance Policy for High Voltage Circuit Breakers in Power Plants

  Electric power industry have always try to provide reliable electricity to customers and at the same time decrease system costs. High Voltage circuit-breakers are an essential part of the power network. This study has developed a maintenance and replacement scheduling model for high voltage circuit- breakers that minimize maintenance costs while maintaining the acceptable reliability. This mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014