Treatment of comminuted subtrochanteric fractures by dynamic hip screw.

نویسنده

  • M Ali
چکیده

Twenty four cases of fracture of the proximal femoral shaft treated with dynamic hip screw fixation are included. All had severe comminution with subtrochanteric extensions. Dynamic hip screw provided stable osteosynthesis and helped to achieve bone union within 18 weeks in 19 of 21 followed-up cases. The anatomical configuration of the femur was maintained with minimal limb length discrepancy in one case and knee flexion of more than 110 degrees in all. Weight bearing was achieved after a mean period of 7.5 weeks post-fixation. Complications of treatment are also presented. Different implants are used to treat this injury with variable results. Dynamic hip screw system is a satisfactory implant for internal fixation in patients with these difficult fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تکنیک صفحه‌گذاری بیولوژیک در شکستگی‌های چند قطعه‌ای ساب‌تروکانتریک استخوان ران

Background: Comminuted subtrochanteric fractures have been a challenge for orthopedic surgeons in terms of appropriate reduction and stable fixation. Numerous methods have been used for the fixation of comminuted subtrochanteric fractures among which some are accompanied with technical difficulties and complications of their own. Regarding the results of previous studies, we decided to evaluate...

متن کامل

Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures – postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate

BACKGROUND In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the r...

متن کامل

Bridge-plating osteosynthesis of 20 comminuted subtrochanteric fractures with dynamic hip screw.

BACKGROUND A prospective clinical trial was conducted to evaluate the conjunctive use of an extramedullary device and the bridge-plating technique in the treatment of comminuted subtrochanteric fractures with major extension into the femoral shaft. METHODS A Winquist criteria was used to classify 3 fracture patterns. The type 3 fractures were excluded from this study because of great extent o...

متن کامل

Mini-incision dynamic condylar screw fixation for comminuted subtrochanteric hip fractures.

PURPOSE To review the results of indirect reduction and mini-incision dynamic condylar screw (DCS) fixation for comminuted subtrochanteric femoral fractures. METHODS 29 men and 14 women aged 25 to 65 (mean, 44) years with comminuted subtrochanteric femoral fractures underwent indirect reduction and mini-incision DCS fixation. Fractures were classified according to the AO classification (10 ty...

متن کامل

Clinical Results of Complex Subtrochanteric Femoral Fractures with Long Cephalomedullary Hip Nail

PURPOSE Good results of the cephalomedullary nails have been reported in proximal femoral fractures recently. Based on length of nails and shape of screws fixed in a femoral head for proximal fragment fixation, the proper nail length was in dispute. The purpose of this study was to evaluate the clinical and radiological results of a long cephalomedullary hip nail for the treatment of comminuted...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JPMA. The Journal of the Pakistan Medical Association

دوره 45 8  شماره 

صفحات  -

تاریخ انتشار 1995