PROTON RADIOGRAPHY EXPERIMENT BASED ON A 100 MeV PROTON CYCLOTRON*

نویسندگان

  • J. J. Yang
  • X. Zhen
  • T. Ge
  • S. P. Zhang
  • L. Cao
  • T. J. Zhang
  • Z. G. Li
چکیده

A proof-of-principle test-stand for proton radiography is under construction at China Institute of Atomic Energy (CIAE). This test-stand will utilize the 100 MeV proton beam provided by the compact cyclotron CYCIAE-100, which has been built in the year of 2014, to radiograph thin static objects. The assembling of the test-stand components is finished by now. We will carry out the first proton radiography experiment in this July and hopefully we can get the first image before the opening of this conference. In this paper, the designing, constructing and commissioning of the proton radiography system will be described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proton-counting radiography for proton therapy: a proof of principle using CMOS APS technology.

Despite the early recognition of the potential of proton imaging to assist proton therapy (Cormack 1963 J. Appl. Phys. 34 2722), the modality is still removed from clinical practice, with various approaches in development. For proton-counting radiography applications such as computed tomography (CT), the water-equivalent-path-length that each proton has travelled through an imaged object must b...

متن کامل

Assessment of The Relation Between Energy Of Primary Protons And Undesired Neutron Dose During Proton Therapy By Monte Carlo Method

Introduction: High-energy beams of protons offer significant advantages for the treatment of deepseated local tumors. Their physical depth-dose distribution in tissue is characterized by a small entrance dose and a distinct maximum -Bragg peak- near the end of range with a sharp fall-off at the distal edge. Alongside its advantages there are some point that they need to meticul...

متن کامل

توزیع بار الکتریکی محصولات شکافت حاصل از واکنش شکافت اورانیم 238 با پروتونهای 45-69 MeV

 Fission of 238U nuclei was performed by 45-69 MeV protons at the Cyclotron and Radioisotope Center of Tohoku University in Japan. The fission products originated in the reaction were identified by using gamma spectroscopy. The experimental data show that the charge distribution of isobar fission products follows a Gaussian distribution with a standard deviation independent of the selected mass...

متن کامل

Centers of Hadron Therapy on the Basis of Cyclotrons

Hadron therapy hospital centers have become wide spread in the world during the last decade. These centers were created mainly on basis of the cycling accelerators such as cyclotrons and synchrotrons. Now there are several proposals of the proton centers on the basis of linear accelerators. In this report we discuss features, advantages and disadvantages of hadron therapy centers on the basis o...

متن کامل

Advocacy for a Dedicated 70 Mev Proton Therapy Facility

Since 1998 we treated more then 1500 patients with eye tumours at the HZB cyclotron with a 68 MeV proton beam. The 5 years follow up shows a tumour control rate of more then 96%. The combination of a CT/MRT based planning and excellent physical beam conditions like 2 nA in the scattered proton beam, a 0.94 mm distal dose falloff and a dose penumbra of 2.1 mm offers the opportunity to keep side ...