Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes
نویسندگان
چکیده
PURPOSE We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter index, and objective pseudo-accommodation obtained from the double-pass system were compared with root mean square (RMS) total aberration, RMS higher-order aberration, and spherical aberration obtained from the ray-tracing aberrometer. Additionally, parameters of the double-pass system and ray-tracing aberrometer were compared with manifested refraction values and subjective visual acuity, respectively. RESULTS There was no statistically significant correlation between optical quality parameters obtained from the double-pass system and ocular aberrations, except between the Strehl ratio and RMS total aberration (r=-0.566, p=0.018). No significant correlations were found between the parameters of both devices, and manifested refraction values or subjective visual acuity. CONCLUSION Optical quality parameters, especially the Strehl ratio, in multifocal IOL implanted eyes were affected by RMS total aberration. Further studies based on accurate measurements of ocular aberrations and additional optical quality parameters are needed to delineate relationships between optical quality parameters and ocular aberrations in multifocal IOL implanted eyes.
منابع مشابه
Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.
PURPOSE Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL...
متن کاملThrough focus image quality of eyes implanted with monofocal and multifocal intraocular lenses
Intraocular lenses (lOLs) are commonly implanted in cataract surgery. Initially lOLs were mainly monofocal, but at present there are many multifocal lOLs available, which are being implanted. Multifocal lOLs have the potential advantage of reducing the dependence on spectacle correction for near vision after cataract surgery. Because the multifocal lOLs superimpose the near and far images on th...
متن کاملVisual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up
PURPOSE To evaluate and compare the visual acuity outcomes and optical performances of eyes implanted with two diffractive multifocal intraocular lens (IOL) models with either a plate haptic design or a modified-C design. METHODS This retrospective study comprised cataract patients who were implanted with either a plate haptic multifocal IOL model (Acriva(UD) Reviol BB MFM 611 [VSY Biotechnol...
متن کاملClinical outcomes with a new microincisional diffractive multifocal IOL
BACKGROUND To evaluate the refractive outcomes and the optical performance as well as the quality of life in patients implanted with a new diffractive multifocal intraocular lens (IOL). METHODS Prospective, clinical study including 41 cases of patients who underwent cataract surgery and were divided in two groups: group 1, including 20 eyes implanted with the multifocal IOL SeeLens MF (Hanita...
متن کاملOptical aberrations of intraocular lenses measured in vivo and in vitro.
Corneal and ocular aberrations were measured in a group of eyes before and after cataract surgery with spherical intraocular lens (IOL) implantation by use of well-tested techniques developed in our laboratory. By subtraction of corneal from total aberration maps, we also estimated the optical quality of the intraocular lens in vivo. We found that aberrations in pseudophakic eyes are not signif...
متن کامل