Dynamic testing of a four-storey building with reinforced concrete and unreinforced masonry walls: prediction, test results and data set
نویسندگان
چکیده
This paper presents the results of a series of shake-table tests on a half-scale, four-storey building with reinforced concrete and unreinforced masonry walls. Due to the lack of reference tests, the seismic behaviour of such mixed structures is poorly understood. The test unit was subjected to several runs of increasing intensity yielding performance states between minor damage and near collapse. Before the test, the expected peak table accelerations leading to different limit states were estimated using the capacity spectrum method, and the predicted values corresponded rather well to actual sustained accelerations. Next to these analyses, the paper describes the test unit, instrumentation and input motion, and comments on the response of the mixed structure in terms of damage evolution and global response quantities, such as force–displacement response and drift and acceleration profiles. The raw and post-processed data sets are made publically available, and all relevant information with regard to data organisation and post-processing procedure is described in an appendix to this paper. The test serves therefore as a benchmark for the validation of numerical models of such mixed structures. The project aims at providing a foundation for the development of seismic design and assessment methods of mixed structures, which are currently not covered by structural codes, including Eurocode 8. & K. Beyer [email protected] 1 Earthquake Engineering and Structural Dynamics Laboratory (EESD), School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), EPFL ENAC IIC EESD, GC B2 504, Station 18, 1015 Lausanne, Switzerland 2 Earthquake Engineering and Structural Dynamics Laboratory (EESD), School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), EPFL ENAC IIC EESD, GC B2 484, Station 18, 1015 Lausanne, Switzerland 3 Earthquake Engineering and Structural Dynamics Laboratory (EESD), School of Architecture, Civil and Environmental Engineering (ENAC), École Polytechnique Fédérale de Lausanne (EPFL), EPFL ENAC IIC EESD, GC B2 495, Station 18, 1015 Lausanne, Switzerland 4 European Centre for Training and Research in Earthquake Engineering (EUCENTRE), Via Ferrata 1, 27100 Pavia, Italy 123 Bull Earthquake Eng DOI 10.1007/s10518-015-9752-z
منابع مشابه
Effect of Unreinforced Masonry Infill Walls on Seismic Performance of Reinforced Concrete Framed Structures
Unreinforced Masonry infill walls (URM) are commonly used in the Reinforced Concrete (RC) framed structures as interiors and exteriors partition walls. Although they usually are not considered in the structural analysis and design, their influence on the seismic performance of the framed structures is significant. A common practice in the modern and old RC buildings is to remove the URM walls i...
متن کاملSimulation of Masonry Beams Retrofitted with Engineered Cementitious Composites
A thin layer of ductile fiber-reinforced mortar material referred to as Engineered Cementitious Composites, or ECC has been experimentally investigated as a seismic retrofit for unreinforced masonry infill walls in non-ductile reinforced concrete frames. Compression tests of masonry prisms retrofitted with 13mm of ECC were conducted representing the compression strut of a masonry infill under i...
متن کاملScaling unreinforced masonry for reduced-scale seismic testing
When testing multi-storey structures, most testing facilities require the testing of a reduced-scale model. A literature review on tests of scaled masonry structural components revealed that scaling of masonry was rather challenging and often significant differences in stiffness, strength and failure mechanisms between the different sized masonry were reported. This paper addresses the scaling ...
متن کاملResistance of Concrete Masonry Walls with Membrane Catcher Systems Subjected to Blast Loading
This paper describes a methodology for analyzing the impulse pressure response of unreinforced concrete masonry walls that have been retrofitted with membranes that are not bonded to the masonry (catcher systems). Membrane catcher systems can be used to protect building occupants from secondary debris resulting from blast pressure, and the effectiveness of systems comprising polymers, composite...
متن کاملApplication of Near Surface Mounted (NSM) technique for Seismic Retrofitting of Heritage Buildings
The high vulnerability of the cultural buildings due to seismic actions urged researchers to retrofit them using reversible and compatible techniques. The application of fiber reinforced polymer (FRP) for enhancing the structural behavior of masonry buildings, under seismic actions, has been studied by many researchers. The near-surface mounting (NSM) technique is a relatively new retrofitting ...
متن کامل