Calibration of atomic force microscope cantilevers using piezolevers.
نویسندگان
چکیده
The atomic force microscope (AFM) can provide qualitative information by numerous imaging modes, but it can also provide quantitative information when calibrated cantilevers are used. In this article a new technique is demonstrated to calibrate AFM cantilevers using a reference piezolever. Experiments are performed on 13 different commercially available cantilevers. The stiff cantilevers, whose stiffness is more than 0.4 N/m, are compared to the stiffness values measured using nanoindentation. The experimental data collected by the piezolever method is in good agreement with the nanoindentation data. Calibration with a piezolever is fast, easy, and nondestructive and a commercially available AFM is enough to perform the experiments. In addition, the AFM laser must not be calibrated. Calibration is reported here for cantilevers whose stiffness lies between 0.08 and 6.02 N/m.
منابع مشابه
Calibration of colloid probe cantilevers using the dynamic viscous response of a confined liquid
Articles you may be interested in Adhesive-free colloidal probes for nanoscale force measurements: Production and characterization Rev. Improved in situ spring constant calibration for colloidal probe atomic force microscopy Rev. Accurate noncontact calibration of colloidal probe sensitivities in atomic force microscopy Rev. A calibration method for lateral forces for use with colloidal probe f...
متن کاملA virtual instrument to standardise the calibration of atomic force microscope cantilevers.
Atomic force microscope (AFM) users often calibrate the spring constants of cantilevers using functionality built into individual instruments. This calibration is performed without reference to a global standard, hindering the robust comparison of force measurements reported by different laboratories. Here, we describe a virtual instrument (an internet-based initiative) whereby users from all l...
متن کاملGDQEM Analysis for Free Vibration of V-shaped Atomic Force Microscope Cantilevers
V-shaped and triangular cantilevers are widely employed in atomic force microscope (AFM) imaging techniques due to their stability. For the design of vibration control systems of AFM cantilevers which utilize patched piezo actuators, obtaining an accurate system model is indispensable prior to acquiring the information related to natural modes. A general differential quadrature element method (...
متن کاملAccurate Calibration and Uncertainty Estimation of the Normal Spring Constant of Various AFM Cantilevers
Measurement of force on a micro- or nano-Newton scale is important when exploring the mechanical properties of materials in the biophysics and nanomechanical fields. The atomic force microscope (AFM) is widely used in microforce measurement. The cantilever probe works as an AFM force sensor, and the spring constant of the cantilever is of great significance to the accuracy of the measurement re...
متن کاملAn analytic model for accurate spring constant calibration of rectangular atomic force microscope cantilevers
Spring constant calibration of the atomic force microscope (AFM) cantilever is of fundamental importance for quantifying the force between the AFM cantilever tip and the sample. The calibration within the framework of thin plate theory undoubtedly has a higher accuracy and broader scope than that within the well-established beam theory. However, thin plate theory-based accurate analytic determi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 78 4 شماره
صفحات -
تاریخ انتشار 2007