Effects of transducer mass on intramuscular temperature during ultrasound treatments.
نویسندگان
چکیده
CONTEXT A potential variable that could affect rate of temperature elevation with ultrasound is the pressure (mass) that is applied to the transducer head during application. Added pressure could compress the tissue, affecting density and the transmission of ultrasound energy. Little research has been completed to determine the effects of the amount of pressure applied during therapeutic ultrasound in vivo. OBJECTIVE To determine the effects of different applied transducer mass on intramuscular temperature during an ultrasound treatment within the left triceps surae. DESIGN Crossover clinical trial. SETTING Human performance research laboratory. PARTICIPANTS Convenience sample of thirteen healthy, college-age students. INTERVENTIONS Three separate 3-MHz, 1.0-W/cm2 ultrasound treatments were administered 1.5 cm within the triceps surae. The independent variables were the linear temperature standards (0.5°C, 1.0°C, 1.5°C, and 2.0°C above baseline) and the 3 different applied pressures measured in grams (200 g, 600 g, and 800 g). MAIN OUTCOME MEASURES A thermocouple probe was used to measure triceps surae temperature, and time to reach the temperature standards was recorded during the ultrasound treatments. A 4 × 3 repeated-measures analysis of variance (RM-ANOVA) was used to analyze the differences for temperature points (0.5°C, 1.0°C, 1.5°C, and 2.0°C) and transducer mass (200 g, 600 g, and 800 g) and with respect to time. RESULTS The results of the RM-ANOVA showed no temperature-point and transducer-mass interaction (F6,72 = 1.69, P = .137) or main effect for mass (F2,24 = 1.23, P = .309). The time required to raise temperature 2°C was 209.1 ± 68.10 s at 200 g, 181.5 ± 61.50 s at 600 g, and 194.9 ± 75.54 s at 800 g. CONCLUSIONS Under the conditions of this study, the amount of mass applied with the transducer during an ultrasound treatment does not ultimately affect the rate of tissue heating.
منابع مشابه
Intramuscular temperature differences between the mid-point and peripheral effective radiating area with ultrasound.
The purpose of the study was to determine whether uniform intramuscular heating is achieved throughout a treatment area 2 times the transducer head at both 1 and 3 MHz. Seven male and three female subjects (Age: 23.6 ± 1.0 yrs, Weight: 83.8 ± 23.2 kg, Site Skinfold: 13.9 ± 7.3 mm) underwent two ultrasound treatments (1 and 3 MHz) in the triceps surae muscle group. Thermocouples were inserted at...
متن کاملThe Effects of Intramuscular Electrical Stimulation on Clinical And Sonographic Parameters in Patient With Trigger Points: A Case Series Study
Objective: Myofascial pain syndrome is a common disorder with a prevalence of up to 85%. It is characterized by the presence of trigger points, which all people are commonly encountered at least once throughout their lifespan. Different physical therapy and medical treatments have used to manage myofascial pain syndrome. Intramuscular electrical stimulation intervention is a relatively new trea...
متن کاملUltrasound heating is curvilinear in nature and varies between transducers from the same manufacturer.
CONTEXT Ultrasound heating rates are known to differ between various manufacturers; it is unknown whether this difference exists within a manufacturer. OBJECTIVE Determine if intramuscular heating differences exist between transducers from the same manufacturer. STUDY DESIGN 3 x 10 repeated measures. Independent variables were Transducer (A, B, and C) and Time (10-min time points during the...
متن کاملEffect of coupling medium temperature on rate of intramuscular temperature rise using continuous ultrasound.
OBJECTIVE We determined the effects of coupling medium temperature on the rate of intramuscular temperature rise (RTR) during continuous ultrasound. DESIGN AND SETTING Ultrasound was applied in a continuous mode at a frequency of 1 MHz and intensity of 1.5 W/cm(2). Each subject received 3 treatments, using water-based coupling gel at temperatures of 18 degrees C, 25 degrees C, and 39 degrees ...
متن کاملA Comparison of Intramuscular Temperatures During 10-Minute 1.0-MHz Ultrasound Treatments at Different Intensities
Context: Research on therapeutic ultrasound has not focused on the duration needed to cause thermal change with various ultrasound intensities. Objective: To analyze triceps surae intramuscular temperature using 4 intensity levels after a 10-min 1-MHz continuous ultrasound treatment at a depth of 4 cm. Design: 1 4 repeated measures. Independent variable: intensity of 4 levels—0.5, 1.0, 1.5, and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sport rehabilitation
دوره 22 4 شماره
صفحات -
تاریخ انتشار 2013