Noncompliance maxillary molar distalization with the first class appliance: a randomized controlled trial.

نویسندگان

  • Moschos A Papadopoulos
  • Aristides B Melkos
  • Athanasios E Athanasiou
چکیده

INTRODUCTION The aim of this study was to evaluate the treatment effects of the First Class Appliance (FCA) (Leone, Firenze, Italy) used for the distalization of maxillary first molars in patients with Class II malocclusion and mixed dentition. METHODS According to the results of the power analysis for sample size calculation, 32 consecutive patients with bilateral Class II molar relationships were initially included in the study. After application of the inclusion and exclusion criteria, 26 patients remained for the final evaluation. They were randomized into 2 groups: treatment group (n = 15) and untreated control group (n = 11). Lateral cephalograms and dental casts were obtained before and immediately after distalization for the treatment group, and initially and approximately 22 weeks later for the control group. Statistical evaluation of the variables included the mixed 2-way analysis of variance at P <0.05. The method error was also estimated. RESULTS The mean treatment period to achieve a full Class I molar relationship was 17.2 weeks. Analysis of the data showed significant distalization of the maxillary first molars produced by the FCA (mean: 4.00 mm) when compared with the untreated group (mean: 0.95 mm). The rate of molar movement was 1.00 mm per month, which, however, was associated with distal tipping of the first molars (8.56 degrees ) and anchorage loss of the anterior dental unit in terms of overjet increase (0.68 mm), and mesial movement (1.86 mm) and inclination (1.85 degrees ) of the first premolars or first deciduous molars. The maxillary first molars also moved buccally (1.37 mm), but no significant distal rotation occurred. CONCLUSIONS The FCA is an efficient noncompliance appliance to distalize molars in the mixed dentition without distal rotations. However, these movements are associated with distal molar tipping and anchorage loss of the anterior teeth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined treatment with headgear and the Frog appliance for maxillary molar distalization: a randomized controlled trial

OBJECTIVE To evaluate the efficiency of the Frog appliance (FA) alone or in combination with headgear for distalizing the maxillary molars. METHODS Fifty patients (25 males and 25 females) aged 12.6 - 16.7 years who received treatment for Class II malocclusion at the Orthodontic Clinic of Al-Baath University were selected for this study and randomly divided into 2 equal groups. Maxillary mola...

متن کامل

Molar distalization with 2K appliance: one-year follow-up

Correction of class II molars in growing patients with acceptable facial profile can be performed by distalization of maxillary first molars. However, in patients where compliance is difficult intraoral means of molar distalization is required. This case report describes the use and effectiveness of a novel 2K appliance in an 11-year-old female having an orthognathic profile, skeletal Class I r...

متن کامل

Maxillary molar distalization with noncompliance intramaxillary appliances in Class II malocclusion. A systematic review.

OBJECTIVE To use published data to evaluate quantitatively the dental effects of noncompliance intramaxillary appliances in individuals with Class II malocclusion. MATERIALS AND METHODS A literature search was carried out identifing 13 prospective or retrospective clinical studies matching inclusion criteria. Only appliances with conventional anchorage designs were considered for the review. ...

متن کامل

Molar Uprighting Using Mini-Screws after Distalization by the Pendulum Appliance: A Case Report

A 16-year-old Class II female patient was treated without tooth extraction. The upper first molars were distalized by the Pendulum appliance. After six months, the molars tipped significantly to the distal. To correct this side effect, we decided to upright the molars using skeletal anchorage. On each side, a mini-screw was inserted between first and second premolars in the buccal cortical plat...

متن کامل

Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization.

INTRODUCTION Conventional anchorage appliances rely exclusively on intraoral anchorage for noncompliance molar distalization. The partial coverage of the palate, in particular, often results in compromised oral hygiene. An innovative alternative combines a skeletonized distal jet appliance with 2 paramedian miniscrews for additional anchorage. The objectives of this study were to investigate th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics

دوره 137 5  شماره 

صفحات  -

تاریخ انتشار 2010