The effect of velocity on the appearance of embolic signals studied in transcranial Doppler models.

نویسندگان

  • D W Droste
  • H S Markus
  • D Nassiri
  • M M Brown
چکیده

BACKGROUND AND PURPOSE Transcranial Doppler ultrasound can be used to detect circulating cerebral emboli. Recent studies have demonstrated that embolus size is significantly related to both the relative intensity increase and duration of an embolic signal. This may allow information about embolus size to be obtained by analysis of Doppler embolic signals. However, theoretically duration will be inversely related to velocity, and therefore velocity may need to be accounted for if information on embolus size is to be derived from the duration of Doppler embolic signals. METHODS The relation between velocity and both relative intensity increase and duration of embolic signal was investigated in an in vitro flow model, a sheep carotid artery model, and in patients with prosthetic heart valves. The same standard transcranial Doppler ultrasound machine was used for all studies. Embolic signals resulting from 99 glass microspheres (size, 210 to 250 microns) were studied in the in vitro model, as were those from 64 glass microspheres (size, 105 to 150 microns) in the sheep model. Embolic signals recorded from the six middle cerebral arteries of three patients with prosthetic cardiac valves were also studied. RESULTS There was a significant (P < .001) inverse relation between velocity and duration of high-intensity signal (in vitro model, r = -.82; sheep model, r = -.43); the exact relations were described using best-fit equations. Correlation coefficients for this relation in patients varied between -.30 and -.55. There was also an unexpected significant positive relation between velocity and intensity in the sheep model (r = .44, P < .001) but not in the in vitro model (P > .05). This relation was also seen in some, but not all, patients. CONCLUSIONS When the duration of embolic signals is used to provide information about the relative size of an embolus, the velocity of the embolic signal should be taken into account. A relation between velocity and relative intensity increase was found in the sheep model and in some patient recordings. It is suggested this relation may result from greater power being supplied to emboli traveling at higher velocities in the center of the vessel; this may occur under certain recording conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Results of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics

Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

Transcranial doppler sonography diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine

Background: An imbalance of the cerebrovascular response during functional activation of the brain has been postulated as a factor in the pathophysiology of migraine. The purpose of this study was to determine the transcranial doppler sonography (TDS) diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine. Methods: This study was carried out on 46 pa...

متن کامل

High-resolution emboli detection and differentiation by characteristic postembolic spectral patterns.

BACKGROUND AND PURPOSE High-intensity transient signals (HITS) detected by transcranial Doppler ultrasonography correspond to microemboli in intracranial arteries. The purpose of this study was to develop new diagnostic criteria for the differentiation of these microembolic signals from artifact, based on a high-resolution analysis of Doppler power spectra in an in vitro model. METHODS Two hu...

متن کامل

مقایسه سرعت جریان خون شریان مغزی میانی در زنان حامله پره اکلامپتیک و زنان حامله نرمال با استفاده از داپلرترانس کرانیال

    Background & Aim: Preeclampsia is the major cause of maternal and perinatal morbidity and mortality. Transcranial Doppler(TCD) as a noninvasive procedure is used to assess hemodynamic changes in middle cerebral artery(MCA). Knowing the influence of normal pregnancy and preeclampsia on brain hemodynamics is essential for proper management of anesthesia, labor and vasoactive drug usage in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 25 5  شماره 

صفحات  -

تاریخ انتشار 1994