Rapid kinetic spectrophotometric determination of phosalone (Zolone) in a commercial formulation.
نویسندگان
چکیده
A kinetic study of the degradation of phosalone in an alkaline medium was undertaken by using a pneumatic stopped-flow system. A rapid semiautomatic method is proposed for determining phosalone. Linear calibration graphs up to 8.0 x 10(-5) M (detection limit = 1.40 x 10(-6) M) were obtained, with a measurement period of only 3.5 s per sample and a relative standard deviation of 1.4%. Several pesticides were assayed as interference species, and several did not interfere even at a 6:1, M:M foreign species/phosalone ratio. A strong interference (ratio < 1) was generated by azinphos-methyl and carbaryl. The proposed method was applied to the analysis of a commercial formulation, and the results were validated by comparison with those for a chromatographic method.
منابع مشابه
Kinetic spectrophotometric determination of trace amounts of nitrite ion using potassium bromate-murexide mixture in acidic media
A new, simple, rapid, and cheap method for determination of trace amounts of nitrite ion is reported.Determination is based on reduction of bromate ion by nitrite ion, in the presence of murexide inacidic media. During reaction of bromate ion with nitrite ion, the reaction mixture is decolorized.The absorbance changes is then monitored spectrophotometricaly at 520 nm, at 25 °C. Dynamicrange of ...
متن کاملKinetic-Spectrophotometric Determination of Thiocyanate Based on Its Inhibitory Effect on the Oxidation of Pyrogallol Red by Bromate
A kinetic spectrophotometric method for rapid measurement of thiocyanate in serum, urine and sewage water with no need for removed of interfering substances in described. The method is based on the inhibitory effect of thiocyanate on the oxidation of pyrogallol red by bromated and nitrite which is monitored at 467 nm. The variables affecting the rate of the reaction were investigated and th...
متن کاملSpectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run
A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...
متن کاملKINETIC DETERMINATION OF ASCORBIC ACID a WITH SPECTROPHOTOMETRIC DETECTION
A simple and rapid method has been developed for the determination of ascorbic acid in fruit and pharmaceutical products. The method is based on the measurement of the reaction rate between ammonium molybdate and ascorbic acid in acidic media. The reaction was monitored spectrophotometrically at 800 nm by fixed-time and variable-time methods. The calibration graph was linear in the range of...
متن کاملKinetic-Spectrophotometric Determination of Track Amounts of Nitrite Ion Based on Its Reduction Reaction with Thionine in Acidic Media
A simple, sensitive and rapid method for determination of trace amounts of nitrite ion in real samples is reported. The reaction is initiated by adding known volumes of a nitrite ion solution of identified concentration to acidic solutions of thionine which causes decolorizaiton of reagent with time. The absorbance changes is then monitored spectrophotometrically at l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of AOAC International
دوره 83 1 شماره
صفحات -
تاریخ انتشار 2000