Median sternotomy and ventral stabilisation using pins and polymethylmethacrylate for a comminuted T5 vertebral fracture in a Miniature Schnauzer.
نویسندگان
چکیده
A 2.9 kg Miniature Schnauzer was referred to our clinic, the Emergency & Critical Care Medicine Service at the Michigan State University Veterinary Teaching Hospital, following a dog fight. Physical examination findings upon admission included multiple thoracic wounds, absence of hindlimb deep pain, and marked Schiff-Sherrington syndrome. Computed tomography imaging revealed thoracic wall penetration and a comminuted T5 vertebral fracture. Thoracic exploration and thoracic wall repair were performed through a median sternotomy. The vertebral fracture was exposed and stabilised intra-thoracically through the same approach using pins and polymethylmethacrylate. The pins were placed percutaneously into the vertebral bodies of the adjacent vertebrae. Recovery was uncomplicated and fracture healing was documented eight weeks postoperatively. Spinal trauma secondary to dog fights is relatively common. The presence of concurrent penetrating thoracic injury negatively affects prognosis and necessitates thoracic exploration as soon as feasible. The approach should allow complete thoracic exploration to repair parietal and visceral damage, thus indicating the need for median sternotomy rather than an intercostal approach. The present case report suggested that median sternotomy can be used to safely apply stabilisation devices for the treatment of concurrent spinal trauma. Direct visualisation of the vertebral bodies permitted optimal implant anchorage as compared to potentially more hazardous techniques such as dorsal pinning.
منابع مشابه
Reestablishment of radiographic kidney size in Miniature Schnauzer dogs
Kidney size may be altered in renal diseases, and the detection of kidney size alteration has diagnostic and prognostic values. We hypothesized that radiographic kidney size, the kidney length to the second lumbar vertebra (L2) length ratio, in normal Miniature Schnauzer dogs may be overestimated due to their shorter vertebral length. This study was conducted to evaluate radiographic and ultras...
متن کاملEpithelialization Over a Scaffold of Antibiotic-Impregnated PMMA Beads: A Salvage Technique for Open Tibial Fractures with Bone and Soft Tissue Loss When all Else Fails
The management of soft tissue defects in tibial fractures is essential for limb preservation. Current techniques are not without complications and may lead to poor functional outcomes. A salvage method is described using three illustrative cases whereby a combination of flaps and antibiotic-impregnated polymethylmethacrylate beads are employed to fill the bony defect, fight the infection, and...
متن کاملConservative management with external coaptation technique for treatment of a severely comminuted fracture of the proximal phalanx in a Holstein-Friesian cow
A 3-year-old Holstein-Friesian cow was evaluated because of sudden onset of right hind limb lameness and pain with fetlock swelling for 2 days. Based on the history, clinical index scores and computed radiographic examinations, the case was accurately diagnosed to be a severely comminuted fracture of the proximal phalanx. This cow was assigned for conservative treatment with external coaptation...
متن کاملLocal osteopenia associated with management of intra-articular distal radial fractures by insertion of external fixation pins in the distal fragment: prospective study.
PURPOSE To assess the restoration of the bone mass of the distal radius following the use of implants in the distal radial fragment. Highly comminuted Frykman type 7 and 8 fractures were studied to determine whether the use of fixation pins in the comminuted distal radial fragment leads to osteopenia in the distal radial fragment after healing of the fracture. METHODS As part of a clinical tr...
متن کاملStabilisation of scoliosis in two koi (Cyprinus carpio).
Two koi (Cyprinus carpio) from the same pond developed similar lesions of scoliosis. Radiographic examinations showed that their spines had become malaligned as a result of vertebral compression fractures involving T14 to T16. The vertebrae in both fish were stabilised with screws, k-wire and polymethylmethacrylate. They both appeared to improve after surgery, but they began to decline and died...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Veterinary and comparative orthopaedics and traumatology : V.C.O.T
دوره 24 1 شماره
صفحات -
تاریخ انتشار 2011