Select Listing of Scientific Papers and Posters Citing Aspect Imaging M-Series Compact MRI Systems

ثبت نشده
چکیده

A majority of MRI procedures requiring intravascular injections of contrast agents are performed with paramagnetic chelates. Such products induce vascular signal enhancement and they are rapidly excreted by the kidneys. Unfortunately, each chelate is made of only one paramagnetic ion, which, taken individually, has a limited impact on the MRI signal. In fact, the detection of molecular events in the nanomolar range using T1weighted MRI sequences requires the design of ultra-small particles containing hundreds of paramagnetic ions per contrast agent unit. Ultra-small nanoparticles of manganese oxide (MnO, 6–8 nm diameter) have been developed and proposed as an efficient and at least 1000 more sensitive “positive” MRI contrast agent. However no evidence has been found until now that an adequate surface treatment of these particles could maintain their strong blood signal enhancement, while allowing their rapid and efficient excretion by the kidneys or by the hepatobiliairy pathway. Indeed, the sequestration of MnO particles by the reticuloendothelial system followed by strong uptake in the liver and in the spleen could potentially lead to Mn2+-induced toxicity effects. For ultra-small MnO particles to be applied in the clinics, it is necessary to develop coatings that also enable their efficient excretion within hours. This study demonstrates for the first time the possibility to use MnO particles as T1 vascular contrast agents, while enabling the excretion of >70% of all the Mn injected doses after 48 h. For this, small, biocompatible and highly hydrophilic pegylated bis-phosphonate dendrons (PDns) were grafted on MnO particles to confer colloidal stability, relaxometric performance, and fast excretion capacity. The chemical and colloidal stability of MnO@PDn particles were confirmed by XPS, FTIR and DLS. The relaxometric performance of MnO@PDns as “positive” MRI contrast agents was assessed (r1 1⁄4 4.4 mM 1 s 1, r2/r1 1⁄4 8.6; 1.41 T and 37 C). Mice were injected with 1.21 mg Mn per kg (22 mmol Mn per kg), and scanned in MRI up to 48 h. The concentration of Mn in key organs was precisely measured by neutron activation analysis and confirmed, with MRI, the possibility to avoid RES nanoparticle sequestration through the use of phosphonate dendrons. Due to the fast kidney and hepatobiliairy clearance of MnO particles conferred by PDns, MnO nanoparticles can now be considered for promising applications in T1-weighted MRI applications requiring less toxic although highly sensitive “positive” molecular contrast agents. Article The Royal Society of Chemistry 2014 vol.2

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Evaluation of Digital Imaging Studies in an Outpatient Orthopedic Setting

Background: Distribution of radiographic images in the outpatient setting on compact discs-recordable (CD-R) iscommonplace. Opening, manipulating and interpreting these can be challenging. This study evaluated the availabilityand ease of use of CD-R to evaluate digital images in an outpatient orthopedic setting.Methods: 118 CD-R containing diagnostic studies were evaluated by ...

متن کامل

قابلیت MRI در بررسی آسیب های غضروف مفصلی در بیماران مبتلا به استئوآرتریت مفصل زانو: مروری نظام مند بر مطالعات گذشته

Background and purpose: Osteoarthritis is a common degenerative joint disease affecting the synovial joints. Cartilage lesion is an important disorder at different degrees associated with osteoarthritis. The purpose of this systematic review was to determine whether magnetic resonance imaging (MRI) is a valid and reliable tool to detect the articular cartilage lesions in patients with knee oste...

متن کامل

Assessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements

Introduction:  Image  distortion  is  one  of  the  major  problems  of  magnetic  resonance  imaging  (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is  widely known that the most obvious effect of the inhomogenity of the magnetic fields and the  nonlinearity  of  the  gradient  is  the  Geometric  Distortion  of  MR  tomograms.  In  this  study,  the...

متن کامل

Diagnosis of Meningitis Caused by Pathogenic Microorganisms Using Magnetic Resonance Imaging: A Systematic Review

Introduction: Bacterial meningitis is an acute infectious inflammation of the protective membranes covering the brain. Its early diagnosis is vital because of its high morbidity and mortality. It is mostly diagnosed by a gold standard diagnostic tool i.e. Cerebrospinal Fluid (CSF) analysis. However, it is sometimes difficult and or impossible to do this procedure and an alternative diagnostic t...

متن کامل

Phenomenological Approach to Profile Impact of Scientific Research: citation Mining

In this paper we present a phenomenological approach to describe a complex system: scientific research impact through Citation Mining. The novel concept of Citation Mining, a combination of citation bibliometrics and text mining, is used for the phenomenological description. Citation Mining starts with a group of core papers whose impact is to be examined , retrieves the papers that cite these ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015