Novel needle cutting edge geometry for end-cut biopsy.
نویسندگان
چکیده
PURPOSE To introduce and determine the biopsy length performance of the novel enhanced cutting edge (ECE) needle tip design, which contains high inclination angles that allow for more efficient tissue cutting. METHODS ECE and regular two-plane symmetric needle tip's biopsy performance and cutting force are compared over a series of needle insertion experiments into bovine liver under varying levels of internal needle vacuum. An earlier developed needle tip force model is also applied. From these experiments and force model, the effect of needle tip geometry and vacuum on biopsy performance and force is studied. RESULTS Biopsy sample length is on average 22%, 30%, and 49% longer for ECE needles compared to that of regular needles for the internal pressures of 0, -33.9, and -67.7 kPa, respectively. For ECE needles the vacuum level of -67.7 kPa produces on average biopsy lengths that are 41%, 31%, 29%, 45%, and 42% longer compared to no vacuum for two-plane needle tip bevel angles of 10°, 15°, 20°, 25°, and 30°, respectively. The force results show the ECE needle can be inserted with less initial insertion force than the regular two-plane needle for needles where the needle tip is fully contacting the tissue upon insertion. Vacuum is also showed to help lower insertion forces. CONCLUSIONS The novel ECE needle tip design outperforms the regular two-plane symmetric needle by yielding longer biopsy samples and lower insertion forces, thereby demonstrating the benefits of needle geometries that contain higher inclination angles. The use of vacuum further improves the ECE needle tip biopsy sample length and lowers insertion forces.
منابع مشابه
Blade Oblique Cutting of Tissue for Investigation of Biopsy Needle Insertion
Needle biopsy is a common medical procedure where a needle is guided into the body and used to cut and remove tissue for evaluation. The geometry of needle tip and speed of insertion are important to the efficiency of tissue cutting. This study investigates the mathematical model on the needle tip cutting edge, which is divided into several elementary cutting tools (ECT). The cutting edge is mo...
متن کاملAn Instantaneous Rigid Force Model For 3-Axis Ball-End Milling Of Sculptured Surfaces
An instantaneous rigid force model for prediction of cutting forces in ball-end milling of sculptured surfaces is presented in this paper. A commercially available geometric engine is used to represent the cutting edge, cutter and updated part geometries. The cutter used in this work is an insert type ball-end mill. Intersecting an inclined plane with the cutter ball nose generates the cutting...
متن کاملPercutaneous needle biopsy of the mediastinum: review of 94 procedures.
BACKGROUND A number of reports of radiologically guided percutaneous biopsy of mediastinal masses have been described but techniques have varied, particularly the type of needle used. In this study mediastinal biopsies with fine aspiration needles and cutting needles have been compared, sometimes in the same patient. The results are reviewed with particular emphasis on the choice of biopsy need...
متن کاملPERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE
Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complic...
متن کاملPercutaneous lung biopsy with a fine bore cutting needle (Vacu-Cut): improved results using drill technique.
BACKGROUND Percutaneous transthoracic needle biopsy is used in the diagnosis of pulmonary and pleural lesions. The standard procedure using the Vacu-Cut cutting type of needle is the "thrust" technique in which the needle is rapidly forced through the lesion. In our experience this technique has a low yield of histological biopsy specimens. The diagnostic yield of a new biopsy technique ("drill...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 1 شماره
صفحات -
تاریخ انتشار 2012