Shortcomings of using two jet nebulizers in tandem with an aerosol face mask for optimal oxygen therapy.
نویسندگان
چکیده
Herein, a laboratory model which allows measurement of simulated distal airway oxygen percentage at different breathing patterns is described to illustrate the shortcomings of conventional O2 devices and, in particular, the aerosol face mask with two jet nebulizers (AFM-DF) in tandem. A table showing the degree of dilution which occurred during simulation of various breathing patterns while using the AFM-DF is also presented. Data revealed that when 60 percent was desired, 13 of 27 measurements were less than 55 percent. The worst-case scenario for 60 percent desired was 48 percent measured. When 80 percent was desired, less than 70 percent was delivered in 24 of the 27 breathing patterns simulated. Less than 60 percent was measured on 12 occasions, with 51 percent being the lowest measurement. When 100 percent O2 was desired, less than 80 percent was measured in 25 of 27 breathing patterns. Less than 60 percent was measured in ten of those. Fifty percent was the lowest analyzed value for the 100 percent setting. The inadequacy of AFM-DF is described in three case studies. A high-flow nonrebreathing face mask (HFM) to address the subset of patients is also discussed. A peak inspiratory flow prediction chart is also documented and may be useful in setting optimal flows when using high-flow systems. The patients in whom intubation and mechanical ventilation (or use of continuous mask CPAP) are indicated can be more clearly identified with a trial of high-flow O2 therapy (with a system that assures adequate flow to meet the patient's peak inspiratory flow demands). In the remainder of patients, those higher-risk modalities will be precluded.
منابع مشابه
Comparison of Effect of Two Treatment Methods: Oxygen Therapy with Face Mask and Nasal Catheter on Nausea and Vomiting and Comfort in Cesarean section under Spinal Anesthesia
Background: Receiving Oxygen during Cesarean section under spinal anesthesia can be a good way to prevent from nausea and vomiting of mothers and hypoxemia of fetus. This study aimed to compare the effect of two treatment methods of Oxygen therapy with facemask and nasal catheter on vomiting and nausea and patient's comfort during Cesarean section under spinal anesthesia. Methods: This clini...
متن کاملPerformance Comparisons of Jet and Mesh Nebulizers Using Different Interfaces in Simulated Spontaneously Breathing Adults and Children.
BACKGROUND Different types of nebulizers and interfaces are used for the treatment of adults and children with pulmonary diseases. The purpose of this study was to determine the efficiency of a mesh nebulizer (MN) with a proprietary adapter and a jet nebulizer (JN) under different configurations in adult and pediatric models of spontaneous breathing. We hypothesize that delivery efficiency of J...
متن کاملRadioaerosol Pulmonary Deposition Using Mesh and Jet Nebulizers During Noninvasive Ventilation in Healthy Subjects.
BACKGROUND In vivo deposition studies of aerosol administration during noninvasive ventilation (NIV) are scarce in the literature. The aim of this study was to compare radioaerosol pulmonary index and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) of radio-tagged aerosol administered using vibrating mesh nebulizers and conventional jet nebulizers during N...
متن کاملEffect of face mask design on inhaled mass of nebulized albuterol, using a pediatric breathing model.
BACKGROUND Aerosol face mask design and the distance at which the face mask is held from the face affect the delivery of nebulized medication to pediatric patients. OBJECTIVE To measure the inhaled mass of nebulized albuterol with 3 types of pediatric face mask, at 3 different distances from the face, with a model of a spontaneously breathing infant. METHODS We compared a standard pediatric...
متن کاملAerosol kinetics and bronchodilator efficacy during continuous positive airway pressure delivered by face mask.
BACKGROUND Rates of fresh gas flow (FGF) commonly used when continuous positive airway pressure (CPAP) is delivered by face mask theoretically reduce the delivery and availability of therapeutic aerosols. As it may be hazardous for patients with acute respiratory failure to interrupt mask CPAP, the effects of CPAP on aerosol kinetics and bronchodilator efficacy were investigated. METHOD The e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 99 6 شماره
صفحات -
تاریخ انتشار 1991