Influence of Screw Length and Bone Thickness on the Stability of Temporary Implants
نویسندگان
چکیده
The purpose of this work was to study the influence of screw length and bone thickness on the stability of temporary implants. A total of 96 self-drilling temporary screws with two different lengths were inserted into polyurethane blocks (n = 66), bovine femurs (n = 18) and rabbit tibia (n = 12) with different cortical thicknesses (1 to 8 mm). Screws insertion in polyurethane blocks was assisted by a universal testing machine, torque peaks were collected by a digital torquemeter and bone thickness was monitored by micro-CT. The results showed that the insertion torque was significantly increased with the thickness of cortical bone from polyurethane (p < 0.0001), bovine (p = 0.0035) and rabbit (p < 0.05) sources. Cancellous bone improved significantly the mechanical implant stability. Insertion torque and insertion strength was successfully moduled by equations, based on the cortical/cancellous bone behavior. Based on the results, insertion torque and bone strength can be estimate in order to prevent failure of the cortical layer during temporary screw placement. The stability provided by a cortical thickness of 2 or 1 mm coupled to cancellous bone was deemed sufficient for temporary implants stability.
منابع مشابه
The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study
The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study Dr. M. Rismanchian * - Dr. R. Birang ** * Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences....
متن کاملThread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis
Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...
متن کاملEvaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method
longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...
متن کاملImmediate loading in dental implants ( A literature review )
Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...
متن کاملارزیابی میزان ماندگاری، تحلیل استخوان و مشکلات پس از درمان در پروتزهای ثابت متکی بر ایمپلنت به روش All-on-4: مقاله مروری
Background and Aims The purpose of this study was to evaluate the survival rate, mean bone loss and post operative complication of implants inserted in All-on-4 technique . Materials and Methods: The literature was searched using keywords angled implant, All-on-4, tilted implant and graftless technique in the last 10 years (2001 to 2011) and clinical trial article that evaluated survival rate a...
متن کامل