Principles of a quantitative assay for bacterial endotoxins in blood that uses Limulus lysate and a chromogenic substrate.

نویسنده

  • C J Webster
چکیده

Some factors affecting the use of chromogenic substrates with Limulus lysate for assaying bacterial endotoxins in blood have been assessed. It was found that endogenous amidases, which degrade the substrate, could be inactivated by heating serum at 60 degrees C for 15 min. Endotoxin was found not to be removed from serum during clotting. A potent inhibitor of the activated lysate was found to be anti-thrombin II, but specific absorption of anti-thrombin II from plasma reduced only marginally the inhibition of lysate by plasma. The presence of specific antibody to the endotoxin was found not to affect its ability to activate lysate. Inactivation of endotoxin by serum enzymes was biphasic in unheated serum, and most of the activity was destroyed in 3 h at 37 degrees C or in 24 h at 5 degrees C. The relevance of these findings to the objective quantitation of endotoxin activities is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-step, chromogenic Limulus amebocyte lysate assay for endotoxin.

A new reagent for the chromogenic Limulus amebocyte lysate (LAL) assay is described. LAL was formulated for optimal performance in either an endpoint procedure or a kinetic procedure with the chromogenic substrate, buffer, and LAL components colyophilized as a single reagent. The kinetic chromogenic method required an incubating microplate reader coupled to a computer for collection and analysi...

متن کامل

Chromogenic Limulus amoebocyte lysate assay for rapid detection of gram-negative bacteriuria.

A chromogenic Limulus amoebocyte lysate assay was evaluated as a rapid screening test for the detection of clinically significant gram-negative bacteriuria. The development of a distinctive yellow color after the addition of chromogenic substrate to the Limulus amoebocyte lysate-urine reaction mixture was used to measure greater than or equal to 10(5) gram-negative bacteria per ml. A total of 3...

متن کامل

Determination of endotoxin in injectable antibiotic preparations by the chromogenic assay method using a Limulus reagent (Tachypleus hemocyte lysate) and a chromogenic substrate.

The effects of 50 antibiotics on the detection and determination of bacterial endotoxins by the chromogenic method using a Limulus reagent (Tachypleus hemocyte lysate) and a chromogenic substrate of p-nitroaniline derivatives were tested, and the antibiotic concentration for 50% inhibition of the chromogenic reaction in the presence of 0.5 ng of endotoxin (Escherichia coli 0111:B4) per ml was e...

متن کامل

An improved chromogenic substrate endotoxin assay for clinical use.

An improved quantitative assay for endotoxin in plasma was developed after evaluating three different chromogenic substrates and seven methods for removal of plasma inhibitors. Optimal storage conditions for plasma samples prior to assay were also determined. Using chromogenic substrate S2423 with plasma diluted 1/10 in water and heated to 75 degrees C for 5 min to remove inhibitors, a within-b...

متن کامل

Endotoxin Detection in Pharmaceuticals and Medical Devices with Kinetic-QCL, a Kinetic-Quantitative Chromogenic Limulus Amebocyte Lysate Assay.

The observation that endotoxin caused gelation in extracts of Limulus amebocytes has been expanded to the development of an in vitro kinetic, quantitative chromogenic LAL assay (Kinetic-QCL) for the detection of endotoxin in aqueous fluids. Within the last 15 years, the use of Limulus amebocyte lysate to detect and control the presence of pyrogenic substances in pharmaceuticals and medical devi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 12 5  شماره 

صفحات  -

تاریخ انتشار 1980