Evaluation of the revised MicroScan dried overnight gram-positive identification panel to identify Enterococcus species.

نویسندگان

  • P C Iwen
  • M E Rupp
  • P C Schreckenberger
  • S H Hinrichs
چکیده

The revised MicroScan Dried Overnight Gram-Positive Identification panel was evaluated for its efficacy at identifying Enterococcus species in comparison with conventional biochemical tests. Supplemental testing of ampicillin-susceptible Enterococcus faecium for motility and the ability to acidify methyl-alpha-D-glucopyranoside helped recognize E. gallinarum and increased the accuracy of the panel for identifying Enterococcus species to 98.5%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical importance of identifying coagulase-negative staphylococci isolated from blood cultures: evaluation of MicroScan Rapid and Dried Overnight Gram-Positive panels versus a conventional reference method.

We evaluated the clinical usefulness of species identification of blood isolates of coagulase-negative staphylococci as a predictor of the clinical significance of the isolates. In addition, we compared results of species identification obtained with MicroScan Rapid Gram-Positive Identification panels and Dried Overnight (Conventional) Gram-Positive Identification panels with those obtained by ...

متن کامل

Evaluation of MicroScan for identification of Enterococcus species.

Emerging drug resistance of the enterococci necessitates differentiation from group D streptococci and accurate species identification. MicroScan (Baxter Healthcare Corp., West Sacramento, Calif.) has recently developed a microdilution system for identification and antibiotic susceptibility testing of gram-positive cocci. To evaluate the ability of this system to identify Enterococcus species, ...

متن کامل

Multicenter evaluation of the MicroScan Rapid Gram-Negative Identification Type 3 Panel.

The accuracy and performance of the revised MicroScan Rapid Gram-Negative Identification Type 3 Panel (Dade MicroScan Inc., West Sacramento, Calif.) were examined in a multicenter evaluation. The revised panel database includes data for 119 taxa covering a total of 150 species, with data for 12 new species added. Testing was performed in three phases: the efficacy, challenge, and reproducibilit...

متن کامل

Escherichia coli O157:H7 generates a unique biochemical profile on MicroScan conventional gram-negative identification panels.

More than 90% of the strains of Escherichia coli O157:H7 that were identified on a MicroScan gram-negative dried conventional (overnight) panel gave one of two unique biochemical profile numbers that were not detected in other d-sorbitol-negative E. coli or in other strains isolated from pathogenic processes. This suggests that the panel has the capability of being used as a preliminary screeni...

متن کامل

Evaluation of the MicroScan Urinary Combo Panel and API 20E system for identification of glucose-nonfermenting gram-negative bacilli isolated from clinical veterinary materials.

Many isolates of glucose-nonfermenting gram-negative bacilli (NFB) cultured from clinical veterinary specimens are not identified because of the large number of identification tests required. We evaluated two commercial identification systems to determine if they could accurately identify NFB isolated from animals. Of 182 strains of NFB, the MicroScan Urinary Combo Panel (MicroScan, Inc., Campb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 37 11  شماره 

صفحات  -

تاریخ انتشار 1999