Safety of mechanical chest compression devices AutoPulse and LUCAS in cardiac arrest: a randomized clinical trial for non-inferiority
نویسندگان
چکیده
Aims Mechanical chest compression (CC) during cardiopulmonary resuscitation (CPR) with AutoPulse or LUCAS devices has not improved survival from cardiac arrest. Cohort studies suggest risk of excess damage. We studied safety of mechanical CC and determined possible excess damage compared with manual CC. Methods and results This is a randomized non-inferiority safety study. Randomization to AutoPulse, LUCAS, or manual CC with corrective depth and rate feedback was performed. We included patients with in-hospital cardiac arrest or with out-of-hospital cardiac arrest arriving with manual CPR at the emergency department. The primary outcome was serious or life-threatening visceral resuscitation-related damage, assessed blind by post-mortem computed tomography scan and/or autopsy or by clinical course until discharge. Non-inferiority hypothesis: mechanical CC compared with manual control does not increase the primary outcome by a risk difference of > 10% [upper 95% confidence interval (CI)]. We included 115 patients treated with AutoPulse, 122 with LUCAS, and 137 patients received manual CC. Safety outcome analysis was possible in 337 of 374 (90.1%) included patients. The primary outcome was observed in 12 of 103 AutoPulse patients (11.6%), 8 of 108 LUCAS patients (7.4%), and 8 of 126 controls (6.4%). Rate difference AutoPulse-control: +5.3% (95% CI - 2.2% to 12.8%), P = 0.15. Rate difference LUCAS-control +1.0% (95% CI - 5.5% to 7.6%), P = 0.75. Conclusion LUCAS does not cause significantly more serious or life-threatening visceral damage than manual CC. For AutoPulse, significantly more serious or life-threatening visceral damage than manual CC cannot be excluded.
منابع مشابه
Mechanical chest compression for out of hospital cardiac arrest: Systematic review and meta-analysis.
AIM To summarise the evidence from randomised controlled trials of mechanical chest compression devices used during resuscitation after out of hospital cardiac arrest. METHODS Systematic review of studies evaluating the effectiveness of mechanical chest compression. We included randomised controlled trials or cluster randomised trials that compared mechanical chest compression (using any devi...
متن کاملPrehospital randomised assessment of a mechanical compression device in cardiac arrest (PaRAMeDIC) trial protocol
BACKGROUND Survival after out-of-hospital cardiac arrest is closely linked to the quality of CPR, but in real life, resuscitation during prehospital care and ambulance transport is often suboptimal. Mechanical chest compression devices deliver consistent chest compressions, are not prone to fatigue and could potentially overcome some of the limitations of manual chest compression. However, ther...
متن کاملUse of the LUCAS mechanical chest compression device for percutaneous coronary intervention during cardiac arrest: is it really a game changer?
Cardiopulmonary support including closed chest compression is a mainstay in the management of cardiac arrest. However, traditional means (i.e. manual) chest compression may be logistically challenging, especially in patients requiring emergent invasive procedures such as percutaneous coronary intervention for cardiac arrest due to acute myocardial infarction. The LUCAS mechanical chest compress...
متن کاملEnd-tidal CO2 in mechanical versus conventional CPR
Introduction Out-of-hospital cardiac arrest (OHCA) generally has a poor prognosis. The development and use of a mechanical chest compression device has been suggested as a measure to achieve sufficient and continuous cardiopulmonary resuscitation (CPR). The mechanical chest compression device (Autopulse®) consists of a battery-driven board with a band attached that applies a 20% anteriorposteri...
متن کاملOut-of-hospital cardiopulmonary resuscitation with the AutoPulse system: a prospective observational study with a new load-distributing band chest compression device.
OBJECTIVE To evaluate the effectiveness, the safety, and the practicability of the new automated load-distributing band resuscitation device AutoPulse in out-of-hospital cardiac arrest in the midsized urban emergency service of Bonn city. STUDY DESIGN Prospective, observational study. METHODS Measurements of effectiveness were the proportion of patients with a return of spontaneous circulat...