A dual-heterodyne laser interferometer for simultaneous measurement of linear and angular displacements.
نویسندگان
چکیده
Picometer laser interferometry is an essential tool for ultra-precision measurements in frontier scientific research and advanced manufacturing. In this paper, we present a dual-heterodyne laser interferometer for simultaneously measuring linear and angular displacements with resolutions of picometer and nanoradian, respectively. The phase measurement method is based on cross-correlation analysis and realized by a PXI-bus data acquisition system. By implementing a dual-heterodyne interferometer with a highly symmetric optical configuration, low frequency noises caused by the environmental fluctuations can be suppressed to very low levels via common-mode noise rejection. Experimental results for the dual-heterodyne interferometer configuration presented demonstrate that the noise levels of the linear and angular displacement measurements are approximately 1 pm/Hz(1/2) and 0.5 nrad/Hz(1/2) at 1 Hz.
منابع مشابه
Error Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer
A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...
متن کاملModeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm
Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...
متن کاملDevelopment of a Novel Fiber-Coupled Three Degree-of-Freedom Displacement Interferometer
Heterodyne displacement interferometry is a widely accepted methodology capable of measuring displacements with sub-nanometer resolution. The objective of this thesis is to demonstrate a compact, fiber-delivered displacement measuring interferometer which can be used to simultaneously calibrate the linear motion and rotational errors of a translating stage using a single measurement beam. Heter...
متن کاملNoncontact measurement of nerve displacement during action potential with a dual-beam low-coherence interferometer.
We have used a novel phase-referenced heterodyne dual-beam low-coherence interferometer to perform what we believe are the first noncontact measurements of surface motion in a nerve bundle during the action potential. Nerve displacements of approximately 5-nm amplitude and approximately 10-ms duration are measured without signal averaging. This interferometer may find general application in mea...
متن کاملSpectral measurement of the caesium D(2) line with a tunable heterodyne interferometer.
The optical properties of a caesium atomic beam driven on a resonant hyperfine transition in the D(2) line were studied as a function of the probe laser frequency. Using a third off-resonant laser system, a heterodyne interferometer allowed simultaneous absorption and phase shift measurements of either the probe or the coupling laser. The signal features of the probe and coupling laser transmit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 86 12 شماره
صفحات -
تاریخ انتشار 2015