Short- and long-term risk stratification using a next-generation, high-sensitivity research cardiac troponin I (hs-cTnI) assay in an emergency department chest pain population.

نویسندگان

  • Peter A Kavsak
  • Xuesong Wang
  • Dennis T Ko
  • Andrew R MacRae
  • Allan S Jaffe
چکیده

BACKGROUND The next-generation, high-sensitivity cardiac troponin assays can measure quantifiable concentrations of cTn in a majority of individuals, but there are few studies assessing these assays for risk stratification. The present study was undertaken to determine if a research hs-cTnI assay can be useful for predicting death/myocardial infarction (MI), both short- and long-term, in an emergency department acute coronary syndrome (ACS) population. METHODS In a cohort of 383 subjects, originally recruited in 1996, presenting to the emergency department with symptoms suggestive of ACS, the heparin plasma obtained at initial presentation was thawed and measured in 2007 with a research hs-cTnI assay. AccuTnI (Beckman Coulter) measurements were made on these same samples in 2003. The population was divided into 4 groups by hs-cTnI: <5.00, 5.00-9.99, 10.00-40.00, and >40.00 ng/L. Kaplan-Meier, Cox proportional hazards, ROC curves, and logistic regression analyses were used to identify which hs-cTnI concentrations were predictive of death/MI within 10 years after presentation. RESULTS There were significant differences between the hs-cTnI groups for the probability of death/MI up to 10 years after presentation (P < 0.05). At 6 months, patients with hs-cTnI > or =10.00 ng/L were at higher risk for death/MI (hazard ratio >3.7; P < 0.05) compared with those having hs-cTnI <5.00 ng/L. ROC curve analysis for death/MI at 30 days with the hs-cTnI assay had an area under the curve of 0.74 (95% CI 0.65-0.82), with logistic models yielding an optimal assay threshold of 12.68 ng/L. CONCLUSIONS This research hs-cTnI assay appears useful for risk stratification for death/MI in an ACS population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Next-generation, High-sensitivity Research Car- Diac Troponin I (hs-ctni) Assay in an Emergency Department Chest Pain Population. Assessing the Performance of Point-of-care Hemoglobin a 1c Systems

diac troponin I (hs-cTnI) assay in an emergency department chest pain population. Clin Chem 2009;55:1809–15. 3. Wu AHB, Apple FS, Jaffe AS, Jesse RI, Morrow DA, Newby K, et al. National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Use of cardiac troponin and B-type natriuretic peptide or N-terminal proB-type natriuretic peptide for etiologies other than acute corona...

متن کامل

Variation of cardiac troponin I and T measured with sensitive assays in emergency department patients with noncardiac chest pain.

BACKGROUND New-generation high-sensitivity assays for cardiac troponin have lower detection limits and less imprecision than earlier assays. Reference 99th-percentile cutoff values for these new assays are also lower, leading to higher frequencies of positive test results. When cardiac troponin concentrations are minimally increased, serial testing allows discrimination of myocardial infarction...

متن کامل

Comparison of hs-cTnI, hs-cTnT, hFABP and GPBB for identifying early adverse cardiac events in patients presenting within six hours of chest pain-onset.

A recent publication comparing and assessing high-sensitivity cardiac troponin T (hs-cTnT) with heart-type fatty-acid binding protein (hFABP) at presentation in a pooled population of patients included in the FAST II (Fast Assessment of Thoracic Pain) and FASTER I (Fast Assessment of Thoracic Pain by nEuRal networks) studies indicated no incremental value for the diagnosis of myocardial infarct...

متن کامل

Risk stratification in patients with acute chest pain using three high-sensitivity cardiac troponin assays.

AIMS Several high-sensitivity cardiac troponin (hs-cTn) assays have recently been developed. It is unknown which hs-cTn provides the most accurate prognostic information and to what extent early changes in hs-cTn predict mortality. METHODS AND RESULTS In a prospective, international multicentre study, cTn was simultaneously measured with three novel [high-sensitivity cardiac Troponin T (hs-cT...

متن کامل

Biomarkers for predicting serious cardiac outcomes at 72 hours in patients presenting early after chest pain onset with symptoms of acute coronary syndromes.

BACKGROUND Most outcome studies of patients presenting early to the emergency department with potential acute coronary syndromes have focused on either the index diagnosis of myocardial infarction (MI) or a composite end point at a later time frame (30 days or 1 year). We investigated the performance of 9 biomarkers for an early serious outcome. METHODS Patients (n=186) who presented to the e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 55 10  شماره 

صفحات  -

تاریخ انتشار 2009